EasyManua.ls Logo

CDVI PROMI E - Factory Default Values; Code Length; C. Audible Signals; D. Visual Signals

CDVI PROMI E
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
B. Factory default values
Key-in keypad time: 10 seconds.
Door release time: 1 second
Programming time: 2 minutes
5-digit Pin code and master code: 12345
C. Audible signals
1 short beep Press a digit keypad
1 long beep Data validated in programming or access granted
2 short beeps Entry or exit from programming
4 short beeps Data computing error
D. Visual signals
LED colour
Normal operating
programming
Flashing orange Stand-by Data computing error
Orange Programming menu
Green Access granted User number empty
Red User number busy
E. Consumption
In stand-by: 4 mA In use: 15 mA max
II. PROGRAMMING
A. Time outputs
Enter the master code twice (for the first use the master code default value is 12345). The orange LED
lights and two beeps sound to confirm entry into programming mode.
Press ¿0 then enter the ‘key in’ time in seconds: 10 for 10 seconds up to 99 for 99 seconds. The LED lights
off during 1 second and a beep will sound to confirm that the time has been accepted.
Press ¿1, then enter the door release time in seconds: 01 for 1 second up to 99 for 99 seconds. Enter 00 for
a latched output. The LED lights off for 1 second and a beep will sound to confirm that the time has been
accepted.
Press # to exit from programming mode. 2 beeps confirm that unit is back to reading mode.
4 beeps indicate a data computing error.
B. Code length
Enter the master code twice (for the first use the master code default value is 12345). The orange LED and
two beeps sound to confirm entry in the programming mode.
Press ¿2 to program the code length then enter 3, 4, 5, 6, 7 or 8 The LED lights off for 1 second and a beep
sound to confirm that the new code length has been accepted.
IMPORTANT:
When the code length has been modified, the Master code should be reprogrammed, in
the new code format, also while in programming.