PARTS
REPLACEMENT
1.
TONE
ARM
Remove
tone
arm
referring
to
DISASSEMBLY
INSTRUCTIONS,
5.
step
(1)
to
(10)
and
replace.
To
reassemble,
use
DIASSEMBLY
INSTRUC-
TIONS
in
reverse.
Adjust
the
tone
arm
referring
to
ADJUSTMENTS,
3,
5
and
6.
2.
TURNTABLE
SHAFT
Remove
the
three
screws
which
hold
the
turntable
shaft,
and
adjust
the
gap
between
the
turntable
gear
and
ratchet
A
referring
to
the
ADJUST-
MENTS,
4.
Be
sure
to
check
auto
return
opera-
tion.
3.
MOTOR
Remove
bottom
base
in
accordance
with
DISAS-
SEMBLY
INSTRUCTIONS,
3.
Cut
the
near
most
portion
of
primary
wire
to
lug
terminal.
Place
the
unit
on
a
bench
with
the
surface
upward
and
remove
the
four
screws
which
mount
the
motor.
Replace
the
new
motor
and
fasten
it
by
screws.
After
binding
the
primary
wires
to
lug
termina!
tightly
and
solder
them.
4.
CUEING
LEVER
With
DISASSEMBLY
INSTRUCTIONS,
6
as
a
guide,
remove
cueing
lever.
Replace
the
cueing
lever
so
that
it
becomes
parallel
with
the
edge
of
panel
board
when
cueing
lever
lines
up
to
¥
position
(Fig.
21).
5.
CUEING
(LIFTER
SHAFT)
Remove
return
plate
(No.
36
in
EXPLODED
VIEW)
from
sub-chassis.
Remove
lifter
base
(No.
17),
and
remove
tone
arm
support
(No.
27)
from
lifter
shaft.
Pull
out
the
lifter
shaft
in
the
direction
of
downward.
Replace
new
lifter
shaft
after
adhering
10°
CS
silicon
oil.
After
finishing
rea-
ssembling,
be
sure
to
check
the
gap
between
stylus
point
and
record
surface
referring
to
ADJUST-
MENTS,
3.
(Fig.
22)
e7
Belt
guide
Pulley
we
Band(
for
60Hz)
No
Band(for
50Hz)
Connection
pin
Fig.
20
Fig.
21
Fig.
22