14
5.3.2 Maximum, Minimum, and Average
The maximum, the minimum value, and the average value of the measurements data saved can be displayed
and checked. However, it becomes calculation of only the data (data of the same measurement direction) of the
same mark as a memory number "001" (the first data).
When data 001 is + (the CW direction), only + (the CW direction) is.
- (The CCW direction) Only for - (the CCW direction), a case is.
(1) STAT A key is pressed.
(2) As Opposed to Data Measured and Saved
1) The number of data -- With no display
2 Maximum Torque value -- "MAX" Display
3 Minimum Torque value -- "MIN" Display
4 Average Torque value -- "AVE" Display
5.3.3 It is Automatic in Display and Clear
When carrying out repeat measurement, even if it does not push the clear button after a measurement end, a
display can be cleared automatically.
1. Set up the "auto clear time" of a convenient functional numerical value.(5.2 Refer)
2. After a measurement end, if the time set up after the load concerning a detecting element was lost passes, a
display will be cleared.
* When auto clear time is set up, a display is not cleared even if it presses the "CLEAR key."
5.4 Real-time data output
A data output (real-time output mode) can be carried out about 180 times in 1 second.
It can switch every 1/ 12 seconds. The change method 6.5 Change of Output Speed of Data Reference
1Set measurement mode as "real-time output" mode.( Reference 3.1.2)
2If torque load becomes beyond the value set up beforehand,
the data output of the load torque will be carried out.
3If torque load becomes under , a data output will stop.
* During a real-time data output, since the torque display changes at high speed,
it stops being able to be visible very easily.
* When the output of data is not carried out by setup of , even if torque has started,
the torque display has become with "0."
* When is set as "0", the inside of real-time output mode continues taking out data.
The data outside the measurement range is used as a reference value.
Although the data near "0" may be fluctuated also in the time of the no-load,
it is not failure with the condition on data processing.
6 Preservation, Display, and Output of Data
Preservation, a display, and an output can be carried out for data, such as measurement data and the average.
Whenever data press the CLEAR key or require an auto clearance, as soon as memory memorizes,
they output a signal also to a data output terminal.
Statistics data output a signal also to a data output terminal at the same time they display data.