EasyManua.ls Logo

Cely PI100 Series - ECR-PN; ECR-POSNET PROTOCOL (SAMSUNG POLAND VARIANT)

Cely PI100 Series
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TEST AND ADJUSTMENTS
49TPI10EN04
13
7.4. ECR-PN / ECR-POSNET PROTOCOL (SAMSUNG
POLAND VARIANT)
Protocol
Cash Register Scale
E
q
D
1
S
H
S
x
SXWW.WWWkgB
cc
E
x
E
T
/ NAK
D
2
S
H
S
x
PPPPPPPPB
cc
E
x
S
x
SXWW.WWWkgB
cc
E
x
S
x
IIIIIIIIB
cc
E
x
E
T
/ NAK
Where:
E
q
: 0x05h
D
1
: 0x11h D
2
: 0x12h
S
H
: 0x01h S
X
: 0x02h
S: Weight status.
S: 0x53h stable.
U: 0x55h Unstable.
X:
SPACE: 0x20h
U: 0X46h
– : 0x2Dh
PPPPPPPP: 8 characters for price (the first two to zero).
WWWWW: 5 characters for weight.
IIIIIIII: 8 characters for amount (the first two to zero).
.: 0x2Eh
kg: 0x6Bh y 0x67h
B
cc
: Checksum, logic add (XOR) from S to weight
status.
E
x
: 0x03h
E
T
: 0x04h
NOTE:
- If the sequence or the message format that the scale receives is incorrect, the scale
responds with NAK.
- The Xis a character which can take more than one value depending on weight status.
Space (0x20): when the weight is correct.
'U' (0x46) : when the weight is not valid or
erroneous.
'–' (0x2D) : when the weight is negative (for
example: Tare weight without plate).
- When the quantity in absolute value is <1000 the leading zeros are fill with “0” (0x30h), but
if the quantity in absolute value is >=1000 they are fill with “ “ (0x20h).
- If the weight is erroneous (with “-------“ on the display) the scale replace the X and the
weight by FFFFFFF. In the answer to the frame D
2
, the amount is set to zero.
- If the scale has a tare weight, it sends the net weight in the field WWWWW.
- If when the frame D
2
is sent the weight is negative, the scale responds with the introduced
price, negative weight and amount to 0.
- If the scale receives a frame with incorrect format, it responds with NAK.
- The scale takes into account the minimum weight adjustment. If this adjustment has the
value 1 the scale responds with NAK if the weight is lower than 20 steps.
- Between different requests the weight must vary at least 20 steps or pass through zero,
otherwise the scale responds with NAK.
- The minimum variation or zero crossing, and the adjustment of minimum weight, also
concerns to weight request.