Page 7For technical questions, please call 1-800-444-3353.Item 60581
SAFETYOPERATIONMAINTENANCE SPECIFICATIONS
Preparing to Charge
Use this charger only on flooded lead-acid batteries.
Other batteries may be damaged or may overheat, leak, or catch fire.
TO PREVENT SERIOUS INJURY:
Wear ANSI-approved splash-resistant safety goggles and heavy-duty rubber work gloves
whenever connecting, disconnecting, or working near battery.
Battery acid can cause permanent blindness.
1. If necessary to remove battery from vehicle to
charge, always remove grounded terminal from
battery first. Make sure all accessories in the
vehicle are off, so as not to cause an arc.
2. Make sure area around battery is well
ventilated while battery is being charged.
3. Clean battery terminals. Be careful to keep
corrosion from coming in contact with eyes.
4. Add distilled water in each cell until battery acid
reaches level specified by battery manufacturer.
Do not overfill. For a battery without
removable cell caps, such as valve
regulated lead acid batteries, carefully follow
manufacturers recharging instructions.
5. Study all battery manufacturers specific precautions
while charging and recommended rates of charge.
6. Charge battery initially at lowest rate.
7. A marine (boat) battery must be removed and
charged on shore. To charge it on board requires
equipment specially designed for marine use.
SHORTED BATTERIES - will read on ammeter as
a high end peg at beginning of charging process.
If after 5-10 minutes, needle does not move off
high end, the battery probably has a short circuit.
Unplug charger and discontinue use.
Have battery checked by a qualified technician.
COLD BATTERIES - begin charging at a low rate,
increase as battery reaches a normal temperature,
then rate will decrease normally.
DO NOT CHARGE A FROZEN BATTERY.
BATTERIES WITH HYDROMETER EYE: Do not depend
on hydrometer eye to determine battery charge level.
Charger Location
1. Locate charger as far away from
battery as DC cables permit.
2. Never place charger directly above battery
being charged; gases from battery will
corrode and damage charger.
3. Never allow battery acid to drip on charger when
reading electrolyte specific gravity or filling battery.
4. Do not operate charger in a closed-in area
or restrict ventilation in any way.
5. Do not set a battery on top of charger.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CEN-TECH 60581 and is the answer not in the manual?

CEN-TECH 60581 Specifications

General IconGeneral
BrandCEN-TECH
Model60581
CategoryBattery Charger
LanguageEnglish