TRMS Clamp Meter
2
Auto Power Off:
If there is no key or dial operation for 10 minutes, the meter will power
itself off to save battery consumption. This function can be disabled by
press and hold the “HOLD ” button then power the unit on.
Over Load:
When the signal larger than the maximum will be show .
Maximum jaw opening:
40 mm
Dimensions:
207 x 66 x 26 mm
Weight:
Approx. 153g (with battery)
Accessories:
Carrying case, Battery, Test Lead & Instruction Manual.
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ±[ …%reading+…count ]
at 23±5°C, ≦80 %RH. True RMS for VAC and AAC accuracy are
specified from 5% to 100% of range, crest factor CF <1.6 at full scale
& CF < 3.2 at half scale.
3-1 Direct Voltage ( )
Range Resolution Accuracy Overload Protection
6V 0.001V
1% ± 2dgts
600Vrms
60V 0.01V
600V 0.01V
Input impedance: 10 M
3-2 Alternating Voltage ( )
Range Resolution Accuracy Overload Protection
6V 0.001V
1.2% ± 5dgts
(50~500Hz)
600Vrms
60V 0.01V
600V 0.01V
LCD displays 0 when the reading < 20counts (6V range only)
Input impedance: 10 M
3-3 Alternating Current ( )
Range Resolution Accuracy Overload Protection
600A 0.1A
1.9% ± 5dgts(50~60Hz)
2.5% ± 5dgts(45~500Hz)
1000Arms
1000A 1A