Troubleshooting
Problem Possible Causes Likely Solutions
Decreased output. Not enough air pressure and/1.
or air ow.
Loose air ttings.2.
Mechanism contaminated. 3.
Check for loose connections and make 1.
sure that air supply is providing enough air
ow (CFM) at required pressure (PSI) to
the Soda Blasters air inlet. Do not exceed
maximum air pressure.
Tighten the ttings.2.
Have qualied technician clean and lubricate 3.
mechanism and clean the air lter.
Severe air
leakage.
(Slight air leakage
is normal,
especially on
older Soda
Blasters.)
Cross-threaded housing 1.
components.
Loose housing. 2.
Damaged valve or housing.3.
Dirty, worn or damaged valve. 4.
Check for incorrect alignment and uneven 1.
gaps. If cross-threaded, disassemble and
replace damaged parts before use.
Tighten housing assembly. If housing cannot 2.
tighten properly, internal parts may be
misaligned.
Replace damaged components.3.
Clean or replace valve assembly.4.
Follow all safety precautions whenever diagnosing or servicing the
Soda Blaster. Disconnect air supply before service.