3377
DATA
DISPLAYED
IN
THE
SCREEN
1. Current time indication (operating time).
2. Day of the week indication.
3. Heating connected indication symbol.
4. Operating mode indication.
5. Room temperature indication (indicating the need to
change the battery when the "Lo" symbol is flashing).
6. Active programme indication (this reading alternates
with that of the confort schedule every 30 seconds).
7. Assigned temperature indication.
TECHNICAL DATA
Adjustment of Set temperature: 7 to 35 ºC, with intervals
of 1K.
Operating temperature: 0 to 45ºC.
Storing temperature: -10 to 50ºC.
Temperature sensor: internal NTC .
Supply: 2 alkaline batteries LR6, "AA", 1,5 V.
Differential: Adjustable, minimum 0,5 K.
Contact: change-over.
Switching current: 8 ( 3,5) A to 250 V AC.