© Cesab 5 – 39 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Basic option 14 – Activate restrictions on hydraulics via operator profiles
Argument #1
Not used. SEU unit not required
Argument #2
Selection of operator profile
Values Meaning
1 Operator profile 1
2 Operator profile 1-2
3 Operator profile 1-3
4 Operator profile 1-4
5 Operator profile 1-5
6 Operator profile 1-6
7 Operator profile 1-7
8 Operator profile 1-8
9 Operator profile 1-9
10 Operator profile 1-10
Argument #3
Connecting restrictions. The values in argument #3 can be combined
through addition, e.g. value 1 + value 8 = value 9
Values Meaning
1 Block the lift/pressurising of hydraulic function 1
2 Block the lowering/depressurising of hydraulic function 1
4 Block the lift/pressurising of hydraulic function 2
8 Block the lowering/depressurising of hydraulic function 2
16 Block the lift/pressurising of hydraulic function 3
32 Block the lowering/depressurising of hydraulic function 3
64 Block the lift/pressurising of hydraulic function 4
128 Block the lowering/depressurising of hydraulic function 4
Argument #4
Not used