SECTION 7 CESSNA
NORMAL PROCEDURES MODEL 162
GARMIN G300
U.S.
PREFLIGHT INSPECTION (Continued)
1 CABIN (Continued)
14. LOW VOLTS Annunciator - CHECK (verify annunciator is
shown)
LOW VOLTS Annunciator will only be shown if battery
voltage is less than 12.5 volts. Verify battery voltage on
PFD/MFD ENG page.
15. Elevator Trim Control - T/O POSITION
16. Avionics Cooling Fan - CHECK (verify fan is operational)
17. Airplane Weight and Balance - CHECKED and ENTERED
18. AVN MASTER Switch - OFF
19. MASTER Switch (ALT and BAT) - OFF
20. Fire Extinguisher - CHECK (if installed) (verify gage pointer in
green arc)
2 LEFT WING
1. Cabin Door - CHECK (security and condition)
2. Main Wheel Tire - CHECK (proper inflation and general
condition (weather checks, tread depth and wear, etc.))
3. Brake Line - CHECK (security and condition)
4. Wheel Fairings - CHECK (security and condition) (if installed)
5. Fresh Air Vent - CHECK (blockage)
6. Fuel Quantity - CHECK VISUALLY (for desired level)
TAKEOFF IS PROHIBITED WITH LESS THAN ¼ TANK
OF FUEL.
7. Fuel Filler Cap - SECURE and VENT CLEAR
(Continued Next Page)
GRND
MIN
MARKING ON FUEL INDICATOR
T.O.
162PHUS-00
7-6