SECTION 9 CESSNA
PLACARDS AND MARKINGS MODEL 162
GARMIN G300
U.S.
POWERPLANT AND ELECTRICAL INSTRUMENT
MARKINGS
Powerplant and electrical instrument markings and their color code
significance are shown in Figure 9-3. Operation with indications in the
red range is prohibited. Avoid operating with indicators in the yellow
range.
POWERPLANT AND ELECTRICAL INSTRUMENT MARKINGS
Figure 9-2
INSTRUMENT
RED
(LOWER
WARNING)
YELLOW
(LOWER
CAUTION)
GREEN
(NORMAL
OPERATING
RANGE)
YELLOW
(UPPER
CAUTION)
RED
(UPPER
WARNING)
Tachometer
(RPM)
---- ---- 2000 to 2750
RPM
2750* to 3500
RPM
Oil
Temperature
(OIL °F)
---- 0 to 75°F 75 to 220°F 220 to 240°F 240* to 265°F
Oil Pressure
(OIL PSI)
0 to 10 PSI 10 to 30 PSI 30 to 60 PSI 60 to 100 PSI 100* to 140 PSI
Exhaust Gas
Temperature
(if installed)
(EGT °F)
---- ---- 1000 to 1600°F
White Advisory
Carburetor
Temperature
(CARB °F)
5 to 40°F
Battery
Current
(AMPS)
-35 to 35
White Advisory
Bus Voltage
(VOLTS)
-30 to 12.5 12.5 to 15 15 to 16 16 to 30
*Maximum operating limit is lower end of red.
162PHUS-00