Connecting the Flue
12.1 Fitting the coaxial flue (Ø 60/100 Horizontal)
The boiler must only be installed with a flue supplied by the boiler manufacturer.
These kits are supplied separately to the appliance in order to respond to different installation solutions. For more information
with regard to the inlet/outlet accessories consult the flue brochure and the following instructions.. The boiler is predisposed for
the connection to a twin flow concentric gas intake and exhaust duct system.
WARNING!!
The exhaust gas ducts should not be in contact with or close to
inflammable material and should not pass through building structures or
walls made of inflammable material.
When replacing an old appliance, the flue must be changed.
IMPORTANT!!
Ensure that the flue is not blocked.
Ensure that the exhaust gas ducts do not
have leaks
Ø 60/100 mm
CONTENTS:
1X SILICONE O-RING (60mm)
1
X ELBOW (90
O
)
2X WALL SEALS (INTERNAL &EXTERNAL)
1X ALUMINIUM FLUE PIPE INCLUDING TERMINAL (1 METRE - 60/100)
2X FLUE CLAMPS
4X SCREWS
2X SEALS
Once the boiler has been positioned on the wall, insert the elbow into the socket and rotate to the required position. NOTE: It is
possible to rotate the elbow 360
o
on its vertical axis.
Using the flue clamps, seals and screws supplied (Fig 12) secure the elbow to the boiler.
The 1 metre horizontal flue kit (705958) supplied is suitable for an exact
X dimension of 823mm, and the 750mm horizontal
flue kit (705785) is suitable for an exact X dimension of 573mm.
Measure the distance from the face of the external wall to the face of the flue elbow (X - Fig 12), add 22 mm to this
measurement, you now have the total length of flue required (including the terminal), this figure must now be subtracted from
860mm, you now have the total amount to be cut from the plain end of the flue.
Cut the flue to the required length ensuring that the distance between the inner and the outer flue is maintained
(Fig 13).