Boiler installation
- x the boiler support bracket to the wall and align it
- hang the boiler onto the bracket
- remove the front boiler casing
- if installing with the hydraulic bar Kit (optional): unscrew the two
A screws and remove the xing bracket 37. Connect valves and hydraulic
bar connections to the boiler
- if installing with a hydraulic Kit for the rst installation, provide the connection
- check the seal of both the water and gas connections and get rid of any leaks.
The backow preventer drain outlet 35, the heating safety valve 12 and the domestic hot water valve 10 must be connected to a waste water
pipe.