Start Surveying Work
19
5. CONFIGURATION AND OPERATION
5.1 Static Configuration
There are 3 ways to configure the receiver into Static Mode.
A. Using RS232 Port and HcLoader Software in the Office
Connect X91GNSS to your computer through RS232 cable.
Run the software HcLoader and click icon Link to make the
receiver connected with computer.
Click icon Setup to set the sample interval (15S is
recommended) and mask angle of the receiver (13 is
recommended) and choose Data Log mode as Auto, then
click Apply to make the configuration active, click Exit.
Restart the receiver.
B. Using Controller and Software HCGPSSet in the Field
Use RS232 or Bluetooth® port connecting Controller with
receiver.
Tap the icon HCGPSSet on the Controller, choose the right
com port and click Bluetooth® icon if you are using
Bluetooth®.
Click Open, set the sample interval (15S is recommended
and mask angle of the receiver (13 is recommended) you
want and choose the data log mode as Auto, then click
Apply to make the configuration active.
Restart the receiver.
C. Switch Button in the Field
Long press the Switch button until the Record LED off
record LED (the fourth LED) is off.
5.2 Real-Time Kinematic Configuration
To do the RTK, Radio or Ntrip must be chose to be the way to
transmit correction messages, X91 offers both these two ways by
using “CHC Radio + Base Station” or “GPRS Network + CORS”. Now