Universal constant torque V/F curve: Below the rated frequency, the output voltage and frequency change 
linearly, suitable for general mechanical transmission applications such as large inertia fans, punching machines, 
centrifuges, and water pumps
function 
code
name
default 
value
Predetermined area
Parameter Description
F4.02
Torque boost cut-off 
frequency
5 0.00Hz
0.00Hz ~F0.07
F4.03
Multipoint V F Frequency 
Point 3
0.00Hz
F 4.05~F2.04
F4.04
Multi-point V F voltage 
point 3
0.0 %
(0.0 ~ 100.0 ) %
F4.05
Multipoint V F Frequency 
Point 2
0.00Hz
F4.07 ~F4.03
F4.06
Multi-point V F voltage 
point 2
0.0 %
(0.0 ~ 100.0 ) %
F4.07
Multi-point V F frequency 
point 1
0.00Hz 0.00Hz ~ F4.05
F4.08
Multi-point V F voltage 
point 1
0.0 %
(0.0 ~ 100.0 ) %
   ● Custom multi-point V/F curve: the frequency point setting range is 0.00Hz to the rated frequency of the 
           motor, the voltage point setting range is 0.0% to 100% corresponding to 0V to the motor rated voltage, 
           and the setting value of the multi-point V/F curve is usually based on The load characteristics of the 
           motor are set.
Figure 8-5-1 General constant torque linear V/F curve
Output voltage V
Output frequency F
Basic operating 
frequency
Torque raises the 
cut-off frequency
V lift
Vb
Output voltage V
Max output voltage
Based operation frequency
Output frequency f
V/F curve point 1
V/F curve point 2
V/F curve point 3
Figure 8 -5-2 Custom multi-point V/F curve