Using Remote Control
Setting Parameters: none
Query Syntax: FETCh:CURRent:INRush?<PMT> , MEASure:CURRent:INRush?<PMT>
Response Parameters: <NR2>
Header on: :FETCH:CURRENT:INRUSH<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
FETCh [ : SCALar ] : CURRent : CREStfactor?
MEASure [ : SCALar ] : CURRent : CREStfactor? 66201 | 66202
Description:
These queries return the crest factor of current.
Setting Syntax: none
Setting Parameters: none
Query Syntax: FETCh:CURRent:CREStfactor?<PMT> ,
MEASure:CURRent:CREStfactor? <PMT>
Response Parameters: <NR2>
Header on: :FETCH:CURRENT:CRESTFACTOR<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
FETCh [ : SCALar ] : CURRent : THD?
MEASure [ : SCALar ] : CURRent : THD? 66202
Description: These queries return the total harmonic distortion of current.
Setting Syntax:
none
Setting Parameters: none
Query Syntax: FETCh:CURRent:THD?<PMT> , MEASure:CURRent:THD?<PMT>
Response Parameters: <NR2>
Header on: :FETCH:CURRENT:THD<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
FETCh [ : SCALar ] : CURRent : HARMonic : ARRay?
MEASure [ : SCALar ] : CURRent : HARMnoic : ARRay? 66202
Description: These queries return the amplitude of all the harmonic order.
Setting Syntax: none
Setting Parameters: none
Query Syntax: FETCh:CURRent:HARMonic:ARRay?<space><CRD><PMT> ,
MEASure:CURRent:HARMonic:ARRay?<space><CRD><PMT>
Query Parameters: <CRD>, VALUEPERCENT
Response Parameters: <NR2>
Header on:
:FETCH:CURRENT:HARMONIC:ARRAY<space><NR2>,<NR2>
,<NR2>,...up to 101 <RMT>
Header off: <NR2>,<NR2>,<NR2>,...up to 101 <RMT>
Separator 0: <NR2>,<NR2>,<NR2>,...up to 101 <RMT>
Separator 1: <NR2>;<NR2>;<NR2>;...up to 101 <RMT>
Example: none