© CIAS Elettronica S.r.l. Ed. 1.0
Installation Handbook page 50 of 59 MANTA 50 – 80
APPENDICE A
The following is a list of the settings of some modems needed to remotely connect the barriers.
As it can be seen, 2 different settings are provided for each type of modem, i.e., CENTRE
(Operator Terminal which remotely connects the MANTA Barriers) and PLANT (the RS485
interconnection network of the MANTA Barriers).
Digicom Botticelli 56K V.90 Digicom Leonardo56
Centre:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c3 Compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at+ms=9,1,9600,9600 Make the connection only at 9600 bps.
at\n3 Error correction V.42 LAPM/MNP.
ate0 Disable echo of controls..
at&w Store parameters..
Plant:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c3 Compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at+ms=9,1,9600,9600 Make the connection only at 9600 bps.
at\n3 Error correction V.42 LAPM/MNP.
ate0 Disable echo of controls..
ats0=1 Automatic reply after one ring.
at&w Store parameters..
VACF1433VQE
Centre:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c0 Remove compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at\n5 Error correction MNP.
ate0 Disable echo of controls..
at&w Store parameters..
Plant:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c0 Remove compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at\n5 Error correction MNP.
ats0=1 Automatic reply after one ring.
ate0 Disable echo of controls..
at&w Store parameters..