Android Deployment Configurator User Guide
ENABLE
Enable” is to turn on the heater for monitoring the temperature of the device and the
heaters. Please turn on or turn off the heaters depends on the real operating environments.
AUTOMATIC
Click to switch the heater mode between “Automatic” and “Manual”.
If the heater mode is set to be
Automatic”, the heater(s) on device automatically turns on
and off to defrost in response to the temperature change.
Setting
Description
Pre-Heat
Check to enable “Pre-heat” mode to shorten the defrost time.
Defrost Sensitivity
Defrost Sensitivity” is inflexible to be “High” if “Pre-heat” mode
is on while it is configurable when “Pre-heatmode is off.
Turn off “Pre-heat” mode and then set the sensitivity by selecting
from Low, Medium, and High for triggering the heater.
Scan Window Defrost
Check to automatically turn on and turn off the heater to defrost the
scan window.
Duration
If Scan Window Defrost” is enabled, you can further set
Durationwhich is the time period that the scan window keeps
defrosting.
The time unit is minute, and the default duration is 3 minutes.
LCM Defrost
Check to enable the heater to be automatically on and off to defrost
the device display.
Duration
By enablingLCM Defrost”, “Duration” can be set to specify the
time period that the device display keeps defrosting.
The time unit is minute, and the default duration is 3 minutes.

Table of Contents

Other manuals for CipherLab RK25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CipherLab RK25 and is the answer not in the manual?

CipherLab RK25 Specifications

General IconGeneral
BrandCipherLab
ModelRK25
CategoryPDA
LanguageEnglish

Related product manuals