Page #29 background image
Troubleshooting
Fault number
12 34
5
6
7
8
Cause
Remedy
–– ––
Lubricant: excessive, insufficient or
unsuitable
Reduce, top up or replace the lubricant.
––
X
Connecting bolts not tightened properly
Tighten the connecting bolts.
––
X
Mechanical seal worn
Replace the mechanical seal.
––
X
Housing seal defective
Replace the housing seal.
––
X
Shaft sleeve is infiltrated
Replace the shaft sleeve and/or O-ring.
––
XXXPumpdistorted
Check the pipe connections and pump
attachment.
X
X
X
X Motor running on 2 phases
Check the fuse and replace it if
necessary.
Check the cable connections and
insulation.
Tab. 12 Troubleshooting list
550 113 146-900/E BA-2021.06 en-US NI series 29