Safety
2Safety
The manufacturer does not accept any liability caused by
disregarding the entire documentation.
2.1 Intended use
Only use the pump for pumping the agreed pumped media
(→ order data sheet).
Adhere to the operating limits and size-dependent mini-
mum flow rate.
Avoid dry running:
Initial damage, such as destruction of the mechanical seal
and plastic parts, will occur within only a few seconds.
Make sure the pump is only operated with, and never
without, a pumped medium.
Avoid cavitation:
Fully open the suction-side armature and do not use it
to adjust the flow rate.
Do not open the pressure-side armature beyond the
agreed operating point.
Avoid overheating:
Do not operate the pump while the pressure-side arma-
ture is closed.
Observe the minimum flow rate (→ order data sheet).
Avoid damage to the motor:
Do not open the pressure-side armature beyond the
agreed operating point.
Note the maximum permissible number of times the
motor can be switched on per hour (→ manufacturer’s
specifications).
Consult the manufacturer about any other use of the pump.
Pumps delivered without a motor must be assembled into
apumpunitaccordingtotheprovisionsofECMachine
Directive 2006/42/EC.
Prevention of obvious misuse (examples)
Note the operating limits of the pump concerning temper-
ature, pressure, flow rate and motor speed (→ order data
sheet).
The power consumed by the pump increases with increas-
ing density of the pumped medium. To avoid overloading
the pump or motor, stay within the agreed density (→ order
data sheet).
Lower densities are allowed. Adapt the auxiliary systems
accordingly.
When pumping liquids containing solids, ensure the limits
for the proportion of solids and the grain size are main-
tained (→ order data sheet, technical description).
When using auxiliary systems, ensure there is a continuous
supply of the appropriate operating medium.
Pumps used with water as the pumped liquid must not be
used for foodstuffs or drinking water. Use of the pump for
foodstuffs or drinking water must be specified in the order
data sheet.
Only select the setup type according to this operating man-
ual. For example, the following are not allowed:
Hanging base plate pumps in the pipe
Overhead installation
Installation in the immediate vicinity of extreme heat or
cold sources
Installation too close to the wall
2.2 General safety instructions
Take note of the following regulations before carrying out
any work.
2.2.1 Product safety
The pump has been constructed according to the latest tech-
nology and recognized technical safety rules. Nevertheless,
operation of the pump can involve risks to life and health of the
user or third parties and risk of damage to the pump and other
property.
Only operate the pump if it is in perfect technical condition
and only use it as intended, staying aware of safety and
risks, and in adherence to the instructions in this manual.
Keep this manual and all other applicable documents com-
plete, legible and accessible to personnel at all times.
Refrain from any procedures and actions that would
expose personnel or third parties to any risk.
In the event of any safety-relevant faults, shut down the
pump immediately and have the fault corrected by appro-
priate personnel.
In addition to the entire documentation for the product,
comply with statutory or other safety and accident-preven-
tion regulations and the applicable standards and guide-
lines in the country where the pump is operated.
2.2.2 Obligations of the operating company
Safety-conscious operation
Only operate the pump if it is in perfect technical conditio
n
and only use it as intended, staying aware of safety and
risks, and in adherence to the instructions in this manu
al.
Ensure that the following safety aspects are observed and
monitored:
Adherence to intended use
Statutory or other safety and accident-prevention reg-
ulations
Safety regulations governing the handling of haz-
ardous substances
Applicable standards and guidelines in the country
where the pump is operated
Make protective equipment available.
550 113 146-900/E BA-2021.06 en-US NI series 7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Circor ALLWEILER NI Series and is the answer not in the manual?

Circor ALLWEILER NI Series Specifications

General IconGeneral
BrandCircor
ModelALLWEILER NI Series
CategoryWater Pump
LanguageEnglish

Related product manuals