Salinity: Located on the Salinity button, this LED is illuminated when
the button has been pressed to display the salt level reading.
Remote: The part is controlled by a remote control system.
No Flow: This LED is illuminated when the Flow Switch has detected
no flow. This causes the Cell to stop generating chlorine. A flashing
LED indicates that the flow is restored, but there will be a 60 second
delay before generation is reestablished.
Lo Salt: When this LED is flashing, the salt level is near to its minimum
threshold, which is causing the Cell to operate at low efficiency. When
this LED is illuminated steadily, the salt level is too low and Cell has
shut down. The salt level must be raised before operation is restored.
See also "Check Cell" below. See page 10 for information about
adding salt.
Hi Salt: When this LED is flashing, the salt level is higher than
necessary. When this LED is illuminated steadily, the salt level is too
high and the Cell has shut down. The pool water must be diluted with
fresh water before operation is restored. See also "Check Cell" below.
Check Cell: This LED is illuminated when Cell efficiency is greatly
reduced. When illuminated, the Cell has stopped producing chlorine.
The Electrolytic Cell must be inspected and cleaned: remove power
from the system, and clean Cell according to the instructions on page
19. If after cleaning the Check Cell light comes back on after power is
restored to the system, verify salinity and Cell Version setting, and if
necessary clean cell again more thoroughly. It is possible for cleaning
to be necessary even if debris or mineral build-up isn't immediately
visible to the eye. Additionally, if poor and inadequate water flow
through the cell is not allowing titanium plates to be completely
covered by water, this will also cause the system to experience a high
amount of wear. If illuminated after thorough cleanings, verifying
system parameters and complete water coverage in cell, Cell
replacement may be necessary. This light takes priority over any
salinity indicators.