Warning
Do not operate your wireless network device near unshielded blasting caps or in an 
explosive environment unless the device has been modified to be especially qualified for 
such use. 
Statement 245B
Caution The fasteners you use to mount an access point on a ceiling must be capable of 
maintaining a minimum pullout force of 20 lbs (9 kg) and must use a minimum of 4 holes 
on the mounting bracket, or a minimum of 2 holes when mounting on a network box.
Caution This product and all interconnected equipment must be installed indoors within the same 
building, including the associated LAN connections as defined by Environment A of the 
IEEE 802.3af/at Standard.
Note The access point is suitable for use in environmental air space in accordance with section 
300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the 
Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power 
injector in air handling spaces.
Note Use only with listed Information Technology Equipment (ITE) equipment. For more 
information on ITE equipment, refer to article 645 of the latest National Electrical Code 
(NEC).