If you cannot safely view and access the component, remove the server from the rack.
Caution
Step 3 Remove the top cover from the server as described in Removing the Server Top Cover, on page 30.
Step 4 Locate header block J39, pins 5-6, as shown in Service Headers and Jumpers, on page 85.
Step 5 Install a two-pin jumper across J39 pins 5 and 6.
Step 6 Reinstall the top cover and reconnect AC power cords to the server. The server powers up to standby power mode,
indicated when the Power LED on the front panel is amber.
Step 7 Return the server to main power mode by pressing the Power button on the front panel. The server is in main power
mode when the Power LED is green.
When you next log in to Cisco IMC, you see a message similar to the following:
'CIMC reset to factory defaults' debug functionality is enabled.
On input power cycle, CIMC will be reset to factory defaults.
Note
Step 8 To remove the jumper, press the Power button to shut down the server to standby power mode, and then remove AC
power cords from the server to remove all power.
Step 9 Remove the top cover from the server.
Step 10 Remove the jumper that you installed.
If you do not remove the jumper, the server will reset the Cisco IMC to the default settiings every time that
you power cycle the server. The jumper has no effect if you reboot Cisco IMC.
Note
Step 11 Replace the top cover, replace the server in the rack, replace power cords and any other cables, and then power on the
server by pressing the Power button.
Cisco APIC M3/L3 Server Installation and Service Guide
91
Maintaining the Server
Using the Reset Cisco IMC to Defaults Header (J39, Pins 5 - 6)