Table 4: Physical Specifications
SpecificationDescription
41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above
sea level.
Temperature, Operating
–40 to 149°F (–40 to 65°C)Temperature, non-operating
(when the server is stored or transported)
10 to 90%Humidity (RH), operating
5 to 93%Humidity (RH), non-operating
(when the server is stored or transported)
0 to 10,000 feetAltitude, operating
0 to 40,000 feetAltitude, non-operating
(when the server is stored or transported)
5.5Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
40Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Power Specifications
Do not mix power supply types or wattages in the server. Both power supplies must be identical.
Note
The power specifications for the supported power supply options are listed in the following sections.
770 W AC Power Supply
This section lists the specifications for each 770 W AC power supply (Cisco part number UCSC-PSU1-770W).
Table 5: 770 W AC Specifications
SpecificationDescription
Nominal range: 100–120 VAC, 200–240 VAC
(Range: 90–132 VAC, 180–264 VAC)
AC Input Voltage
Cisco 3375 Appliance for Cisco Connected Mobile Experiences Installation Guide
40
Technical Specifications
Power Specifications