Getting Started and Product Document of Compliance for the Cisco IR1101 Industrial Integrated Services Router
The World Health Organization has stated that present scientific information does not indicate the need for any special
precautions for the use of wireless devices. They recommend that if you are interested in further reducing your exposure
then you can easily do so by reorienting antennas away from the user or placing he antennas at a greater separation
distance then recommended.
This Device Meets FCC Guidelines for Exposure to Radio Waves
The IR1101 series device includes a radio transmitter and receiver. It is designed not to exceed the limits for exposure
to radio waves (radio frequency electromagnetic fields) as referenced in FCC Part 1.1310. The guidelines are based on
IEEE ANSI C 95.1 (92) and include a substantial safety margin designed to ensure the safety of all persons, regardless
of age and health.
As such the systems are designed to be operated as to avoid contact with the antennas by the end user. It is
recommended to set the system in a location where the antennas can remain at least a minimum distance as specified
from the user in accordance to the regulatory guidelines which are designed to reduce the overall exposure of the user
or operator.
The device has been tested and found compliant with the applicable regulations as part of the radio certification process.
The US Food and Drug Administration has stated that present scientific information does not indicate the need for any
special precautions for the use of wireless devices. The FCC recommends that if you are interested in further reducing
your exposure then you can easily do so by reorienting antennas away from the user or placing the antennas at a greater
separation distance then recommended or lowering the transmitter power output.
This Device Meets the Industry Canada Guidelines for Exposure to Radio Waves
The IR1101 series device includes a radio transmitter and receiver. It is designed not to exceed the limits for exposure
to radio waves (radio frequency electromagnetic fields) as referenced in Health Canada Safety Code 6. The guidelines
include a substantial safety margin designed into the limit to ensure the safety of all persons, regardless of age and
health.
As such the systems are designed to be operated as to avoid contact with the antennas by the end user. It is
recommended to set the system in a location where the antennas can remain at least a minimum distance as specified
from the user in accordance to the regulatory guidelines which are designed to reduce the overall exposure of the user
or operator.
Health Canada states that present scientific information does not indicate the need for any special precautions for the
use of wireless devices. They recommend that if you are interested in further reducing your exposure you can easily do
so by reorienting antennas away from the user, placing the antennas at a greater separation distance than recommended,
or lowering the transmitter power output.
Separation Distance
MPE Distance Limit
0.63 mW/cm
2
20 cm (7.87 inches) 1.00 mW/cm
2
Separation Distance
MPE Distance Limit
0.63 mW/cm
2
20 cm (7.87 inches) 1.00 mW/cm
2

Other manuals for Cisco IR1101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IR1101 and is the answer not in the manual?

Cisco IR1101 Specifications

General IconGeneral
DSL WANNo
Ethernet WANYes
SIM card slot-
Cabling technology10/100Base-T(X)
Networking standardsIEEE 802.1D, IEEE 802.1Q
Ethernet LAN data rates10, 100 Mbit/s
Ethernet interface typeFast Ethernet
USB version2.0
USB ports quantity2
Combo SFP ports quantity1
Ethernet LAN (RJ-45) ports4
Output voltage12 - 48 V
Power source typeDC
Power consumption (typical)9.8 W
Operating altitude-152.4 - 1524 m
Operating temperature (T-T)-40 - 60 °C
Operating relative humidity (H-H)10 - 95 %
SafetyUL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1, 2nd edition, EN 60950-1, 2nd edition; CB to IEC 60950-1, 2nd edition
Flash memory8000 MB
Storage mediaFlash
Internal memory4096 MB
Internal memory typeDRAM
Electromagnetic compatibility47 CFR Part 15 B, EN 55032:2015, CISPR 32 Edition 2, CNS13438: 2006, EN 300 386 V1.6.1, ICES-003 Issue 6: 2016, KN 32: 2015, TCVN 7189: 2009, V-2/2015.04, V-3/2015.04, AS/NZ CISPR32, EN 61000-4-2, 3, 4, 5, 6, 8, 9, 16, 17, 18, and 29, CISPR24: 2010 + A1: 2015, EN 300 386 V1.6.1, EN 55024: 2010 + A1: 2015, EN 55035:2017, KN35: 2015, TCVN 7317:2003, QCVN 18:2014
Product colorBlack
Routing protocolsBGP, EIGRP, HSRP, RIP-1, RIP-2
Data link protocolsIPv4, IPv6
Supported protocolsSCADA, DNP3, T101-104, Raw Socket TCP, UDP
Mobile network generationNot supported
VPN supportCisco Easy VPN Solution client and server NAT transparency Dynamic Multipoint VPN (DMVPN) Tunnel-less Group Encrypted Transport VPN Flex VPN
Firewall securityCisco IOS
Security algorithms256-bit AES, HTTPS, IPSec, SSL/TLS
Authentication methodSecure HTTP (HTTPS), FTP, Telnet Authentication Proxy
Harmonized System (HS) code85176990
Weight and Dimensions IconWeight and Dimensions
Depth124.9 mm
Width132.5 mm
Height60 mm
Weight1020 g