Logical Objects: Power
The PATCH-PANEL POWER REDUNDANCY LOST alarm is raised when one of the power supply units
present in the breakout patch-panel is not functional.
Clear the PATCH-PANEL POWER REDUNDANCY LOST Alarm
The alarm clears when the power supply unit is restored.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical
Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or log into
http://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html to obtain a directory of toll-free
Technical Support numbers for your country.
PEM-MODULE-INSERT Alarm
Default Severity: Minor(MN), Non-Service Affecting (NSA)
Logical Objects: PEM
The PEM-MODULE-INSERT alarm is raised on the NCS 1002 when the Power Entry Module (PEM) is
inserted into the chassis.
Clear the PEM-MODULE-INSERT Alarm
This alarm clears automatically.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/
index.html for more information or call Cisco TAC (1 800 553-2447).
PEM-MODULE-REMOVAL Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: PEM
The PEM-MODULE-REMOVAL alarm is raised on the NCS 1002 when one of the redundant PEM module
is removed from the system.
Clear the PEM-MODULE-REMOVAL Alarm
This alarm clears when the redundant PEM module is inserted back into the chassis.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical
Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or log into
http://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html to obtain a directory of toll-free
Technical Support numbers for your country.
POWER MODULE OUTPUT DISABLED Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: PEM
Troubleshooting Guide for Cisco NCS 1002, IOS XR Release 6.3.x