Send document comments to nexus7k-docfeedback@cisco.com
7-25
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Chapter 7      Managing the Switch Hardware
Displaying Environment Information
2        QEng2Sn2(s17)   115             110         68         Ok
2        QEng2Sn3(s18)   115             110         67         Ok
2        QEng2Sn4(s19)   115             110         68         Ok
2        L2Lookup(s27)   115             105         56         Ok
2        L3Lookup(s28)   120             110         63         Ok
5        Outlet1 (s1)    125             125         49         Ok
5        Outlet2 (s2)    125             125         37         Ok
5        Intake  (s3)    60              42          32         Ok
5        EOBC_MAC(s4)    105             95          43         Ok
5        CPU     (s5)    105             95          40         Ok
5        Crossbar(s6)    105             95          61         Ok
5        Arbiter (s7)    110             100         67         Ok
5        CTSdev1 (s8)    115             105         43         Ok
5        InbFPGA (s9)    105             95          44         Ok
5        QEng1Sn1(s10)   115             105         60         Ok
5        QEng1Sn2(s11)   115             105         59         Ok
5        QEng1Sn3(s12)   115             105         56         Ok
5        QEng1Sn4(s13)   115             105         57         Ok
xbar-1   Outlet  (s1)    125             125         38         Ok
xbar-1   Intake  (s2)    60              42          32         Ok
xbar-1   Crossbar(s3)    105             95          56         Ok
xbar-2   Outlet  (s1)    125             125         39         Ok
xbar-2   Intake  (s2)    62              42          31         Ok
xbar-2   Crossbar(s3)    105             95          56         Ok
switch# 
Displaying Environment Information 
You can display all of the environment-related switch information by using the show environment 
command. See Example 7-7.
Example 7-7 Displaying All Environmental Information
switch# show environment
Clock:
----------------------------------------------------------
Clock           Model                  Hw       Status
----------------------------------------------------------
A               Clock Module           --       NotSupported/None
B               Clock Module           --       NotSupported/None
Fan:
------------------------------------------------------
Fan             Model                Hw         Status
------------------------------------------------------
Fan1(sys_fan1)  N7K-C7010-FAN-S      1.1        Ok
Fan2(sys_fan2)  N7K-C7010-FAN-S      1.1        Ok
Fan3(fab_fan1)  N7K-C7010-FAN-F      1.1        Ok
Fan4(fab_fan2)  N7K-C7010-FAN-F      1.1        Ok
Fan_in_PS1      --                   --         Ok
Fan_in_PS2      --                   --         Ok
Fan_in_PS3      --                   --         Ok
Fan Air Filter : Absent
Temperature:
--------------------------------------------------------------------
Module   Sensor        MajorThresh   MinorThres    CurTemp    Status 
                       (Celsius)     (Celsius)     (Celsius)
--------------------------------------------------------------------
2        Crossbar(s5)    105             95           43        Ok