StatusFAIL or FAIL/ID
LED
OK LED
Either all the installed power supplies are not receiving power or an
uninstalled power supply is not receiving power.
OffOff
Power supply is operating but a warning condition has occurred—possibly
one of the following conditions:
High temperature
High power
Slow power supply fan
Low voltage
Power supply is installed in the chassis but was disconnected from
the power source.
Flashing amberOff
Power supply is installed without a connection to a power source.Flashing amber
(10 seconds)
then amber
Off
Power supply failure—possibly one of the following conditions:
Over voltage
Over current
Over temperature
Power supply fan failure
AmberOff
Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide