Loading...
1-17
Cisco ONS 15454 Procedure Guide, Release 8.5.1
78-18537-01
Chapter 1 Install the Shelf and Backplane Cable
NTP- A120 Install an External Wire-Wrap Panel to the AEP
Step 4 Complete the “DLP-A22 Install the TL1 Craft Interface” task on page 17-29 as needed. Craft wires (or
the EIA/TIA-232 port on the TCC2/TCC2P) are required to access TL1 using the craft interface.
Caution Always use the supplied ESD wristband when working with a powered ONS 15454. Plug the
wristband cable into the ESD jack located on the lower-right outside edge of the shelf
assembly.
Step 5 Complete one of the following:
If you installed an AEP, continue with the “NTP-A120 Install an External Wire-Wrap Panel to the
AEP” procedure on page 1-17.
If you did not install an AEP and you plan to install electrical cards, continue with the “NTP-A9
Install the Electrical Card Cables on the Backplane” procedure on page 1-22.
If you did not install an AEP and do not plan to install electrical cards, continue with the “NTP-A11
Install the Rear Cover” procedure on page 1-23.
Stop. You have completed this procedure.
NTP-A120 Install an External Wire-Wrap Panel to the AEP
Step 1 Position the lower cover over the AEP. Make sure that the AEP AMP Champ connectors protrude
through the cutouts in the lower cover (Figure 1-5).
Purpose This procedure connects an external wire-wrap panel to the AEP to provide
the physical alarm contacts for the AEP.
Tools/Equipment External wire-wrap panel
Prerequisite Procedures NTP-A119 Install the Alarm Expansion Panel, page 1-13
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None