Cisco 300 Series Managed Switches 3
Do not deploy the device in a location where any of the following 
conditions exist:
  • High Ambient Temperature—Refer to the following table for the high 
ambient temperature rating of each switch:
  • Reduced Air Flow—Both side panels must be unobstructed to prevent 
overheating.
 • Mechanical Overloading—The device should be level, stable, and 
secure to prevent it from sliding or shifting out of position.
 • Circuit Overloading—Adding the device to the power outlet must not 
overload that circuit.
Ambient Temperature Ratings
Switch Model High Temperature
SF300-24P 104 degrees Fahrenheit (40 Centigrade)
SF300-24PP 113 degrees Fahrenheit (45 Centigrade)
SF300-24MP 122 degrees Fahrenheit (50 Centigrade)
SF300-48P 104 degrees Fahrenheit (40 Centigrade)
SF300-48PP 122 degrees Fahrenheit (50 Centigrade)
SF302-08P 104 degrees Fahrenheit (40 Centigrade)
SF302-08PP 113 degrees Fahrenheit (45 Centigrade)
SF302-08MP 104 degrees Fahrenheit (40 Centigrade)
SF302-08MPP 113 degrees Fahrenheit (45 Centigrade)
SG300-10P 104 degrees Fahrenheit (40 Centigrade)
SG300-10PP 113 degrees Fahrenheit (45 Centigrade)
SG300-10MP 104 degrees Fahrenheit (40 Centigrade)
SG300-10MPP 113 degrees Fahrenheit (45 Centigrade)
SG300-10SFP 113 degrees Fahrenheit (45 Centigrade)
SG300-28P 122 degrees Fahrenheit (50 Centigrade)
SG300-28PP 113 degrees Fahrenheit (45 Centigrade)
SG300-28MP 122 degrees Fahrenheit (50 Centigrade)
SG300-28SFP 122 degrees Fahrenheit (50 Centigrade)
SG300-52P 113 degrees Fahrenheit (45 Centigrade)
SG300-52MP 113 degrees Fahrenheit (45 Centigrade)