EasyManua.ls Logo

Cisco UCS B200 M3 - Page 3

Cisco UCS B200 M3
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 1: Blade Server LEDs
DescriptionColorLED
Power off.OffPower
Main power state. Power is supplied to all server components in
normal operation.
Green
Standby power state. Power is supplied only to the service processor
(BMC) of the server so that the server can still be managed.
If you press and release the front-panel power button, the
server performs an orderly shutdown of the 12 V main
power and goes to standby power state. You cannot shut
down standby power from the front-panel power button.
See the Cisco UCS Manager Configuration Guide for your
release for information about completely powering off the
server from the software interface.
Note
Amber
None of the network links are up.OffLink
At least one network link is up.Green
Power off.OffHealth
Normal operation.Green
Minor error.Amber
Critical error.Blinking Amber
Beaconing not enabled.OffBeaconing
Beaconing to locate a selected bladeIf the LED is not blinking,
the blade is not selected. You can initiate beaconing in UCS Manager
or by using the Locator button.
Blinking blue 1 Hz
Inactive.OffActivity
(Disk Drive)
Outstanding I/O to disk drive.Green
Rebuild in progress. Health LED will flash in unison.Flashing Amber
4 Hz
Identify drive active.Flashing Amber
4 hz
3

Other manuals for Cisco UCS B200 M3

Related product manuals