Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
26
CONFIGURING the SERVER
STEP 8 ORDER POWER SUPPLIES
The C240 M3 server requires two power supplies. A lightly loaded server may require two 650 W
power supplies. A fully loaded server might need to be powered with two 1200 W power supplies
(see
Table 11). Use the power calculator at the following link to determine the needed power
based on the options chosen (CPUs, drives, memory, and so on):
https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Table 11 Power Supply
Product ID (PID) PID Description
UCSC-PSU-650W 650 W power supply (CSCI platinum).
UCSC-PSU2-1200 1200 W power supply (CSCI platinum).
NOTE: In a two power supply server, both power supplies must be identical.

Other manuals for Cisco UCS C240 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M3 and is the answer not in the manual?

Cisco UCS C240 M3 Specifications

General IconGeneral
Processor cores8
Processor modelE5-2600
Processor frequency2.7 GHz
Number of processors installed2
HDD size2.5 \
RAID supportYes
HDD interface-
Optical drive typeNo
Total storage capacity300 GB
Maximum storage capacity- TB
Number of HDDs installed16
Memory slots24
Internal memory96 GB
Memory clock speed1866 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express x8 slots3
Chassis typeRack (2U)
Power supply650 W
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Operating temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth712 mm
Width445 mm
Height87 mm