DS 19 OPERATION No. DS 212-0 Checking an ignition coil. Op. DS 212-0 143
TOOLS
b) Secondary outlet No. 2.
Reverse the secondary wires to the spark gaps.
Put the two-way switch (C) in position to supply the contact breaker (towards the top). There should be
practically no misfires in the sparks with the spark gap set at 8 mm.
Leave running for a quarter of an hour. After this time, there should be no misfires.
Put the two-way switch in the neutral position.
c) Secondary outlet No. 1 (after a quarter of an hour warming up).
Reverse the secondary wires to the spark gaps.
Put the two-way switch (C) in position to supply the contact breaker (towards the top).
The results should be identical to those indicated above.
Put the two-way switch in the neutral position.
Stop the apparatus, disconnect the wires.