EasyManuals Logo
Home>CKD>Controller>AX1000T Series

CKD AX1000T Series User Manual

CKD AX1000T Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
37
TS·TH type driver
PROFIBUS-DP specifications
-
BK
BK +
CN5
U
W
V
C
N
3
T
B
1
MON.
CN4
CHARGE
POWER
C
N
1
C
N
2
G2
G1
SERIES
DRIVER
ABSODEX
T
L3
-230V
50/60Hz
L2C
3AC200
L1C
L2
L1
MODEL AX9□□□GS
CKD Corporation
SERIAL:□□□□□□□
MADE IN JAPAN
ABSODEX
T
B
3
T
B
2
RUN ERR
%QPPGEVQTHQT%0241(+$75&2
㧔㧏70%㧕
Control power supply LED
Main power supply LED
Main power supply
Control power supply
A
ctuator
Output terminal
Ground terminal
2-M4
Operating indication
7 segment LED (2 digit)
Gain 1 dip switch
(Convergence time)
CN1 RS-232C connector
Gain 2 dip switch
(Load)
CN2 resolver cable connector
Terminal for TB1 safety
Transmission monitor LED
TB2 terminal
Terminal for TB3 emergency stop
Parallel I/O (NPN,NPN specifications)
-J1
G2
G1
T
MON.
SERIES
C
N
2
CN4
+ S2
+ S1
C
N
1
ABSODEX
DRIVER
C
N
3
- S2
CN5
T
B
2
BK +
BK -
- S1
T
B
1
CHARGE
POWER
L1
L2
L2C
50/60Hz
-115V
AC100
L1C
U
V
W
CKD Corporation
MODEL: AX9000TS
MAD E IN JA PAN
ABSODEX
SERIAL:+25A1+25A1+25A1+25A1+25A1+25A1+25A1
Operating indication
7 segment LED (2 digit)
Control power supply LED
Gain 1 dip switch
(Convergence time)
CN1 RS-232C connector
Gain 2 dip switch
(Load)
CN2 resolver cable connector
Terminal for TB1 safety
CN3 I/0 connector
TB2 terminal
Main power supply LED
Main power supply
Control power supply
Actuator
Output terminal
Ground terminal
2-M4
Operating indication
7 segment LED (2 digit)
Control power supply LED
Gain 1 dip switch
(Convergence time)
CN1 RS-232C connector
Gain 2 dip switch
(Load)
CN2 resolver cable connector
Terminal for TB1 safety
CN3 I/0 connector
TB2 terminal
Main power supply LED
Main power supply
Control power supply
Actuator
Output terminal
Ground terminal
2-M4
CC-Link specifications
Operating indication
7 segment LED (2 digit)
Control power supply LED
Gain 1 dip switch
(Convergence time)
CN1 RS-232C connector
Gain 2 dip switch
(Load)
CN2 resolver cable connector
Terminal for TB1 safety
Transmission monitor LED
TB2 terminal
CN3 CC-Link connector
Terminal for TB3 emergency stop
Main power supply LED
Main power supply
Control power supply
Actuator
Output terminal
Ground terminal
2-M4
BK +
BK -
- S1
- S2
+ S1
+ S2
T
B
2
T
B
3
C
N
3
T
B
1
C
N
2
C
N
1
MNS
CN5
CN4
MON.
T
W
V
U
3AC200
-230V
50/60Hz
L2C
L1C
L3
L2
L1
CHARGE
G2
G1
POWER
SERIES
DRIVERABSODEX
Control power supply LED
Operating indication
7 segment LED (2 digit)
Gain 1 dip switch
(Convergence time)
Gain 2 dip switch
(Load)
CN1 RS-232C connector
CN2 resolver cable connector
TB1 safety terminal
Transmission monitor LED
CN3 DeviceNet connector
Terminal for TB3 emergency stop
TB2 terminal
Main power supply LED
Control power supply
Main power supply
Actuator
Output terminal
Ground terminal
2-M4
200 VAC
100 VAC
DeviceNet specifications
Panel explanation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CKD AX1000T Series and is the answer not in the manual?

CKD AX1000T Series Specifications

General IconGeneral
BrandCKD
ModelAX1000T Series
CategoryController
LanguageEnglish

Related product manuals