RETURN TO NORMAL MODE
STEP 4C – Set Refi ll option using ▼ or ▲ buttons:
• “PoST” to refi ll the brine tank after the fi nal rinse; or
• “PrE” to refi ll the brine tank two hours before the regeneration time set.
If selecting “Filter” in Step 2F, “POST” should always be selected.
Press NEXT to go to Step 5C. Press REGEN to return to previous step.
STEP 5C – Set regenerant downfl ow or upfl ow using ▼ or ▲ buttons:
• “dn” if the regenerant is to fl ow downward through the media; or
• “UP” if the regenerant is to fl ow upward through the media. Step 2C must be set to 1 for a 1” valve.
Prior to selecting a regenerant fl ow direction, verify the correct valve body, main piston, regenerant
piston, and stack are being used, and that the injector or injector plug(s) are in the correct locations. See
Compliance Table in Service Instructions under Injector Cap, Screen, Injector Plug and Injector section
and Figure 6. This screen will not display if the unit is set up as a 1.25”,1.5”,2” or fi lter valve.
If selecting “Filter” in Step 2F, “dn” should always be selected.
Press NEXT to exit OEM Cycle Sequence. Press REGEN to return to previous step.
STEP 4C
STEP 5C