When desired, all information in Diagnostics may be reset to zero when the valve is installed in a new location. To reset
to zero, press NEXT and ▼ buttons simultaneously to go to the Service/OEM 1 screen, and release. Press ▲ and ▼
simultaneously to reset diagnostic values to zero. Screen will return to User Display.
STEP 6D
STEP 6D – Flow rate, maximum last seven days: The maximum fl ow rate in gallons per minute that
occurred in the last seven days will be displayed. This display will equal zero if a water meter is not
installed. Press the NEXT button to exit Diagnostics. Press REGEN to return to previous step.
STEP 7D – Gallons, total used since start-up: This display shows the total gallons treated since startup.
This display will equal zero if a water meter is not installed. Press the NEXT button to go to Step 8D.
Press REGEN to return to previous step.
STEP 7D
STEP 8D – Days, total since start-up: This display shows the total days since startup. Press the NEXT
button to go to Step 9D. Press REGEN to return to previous step.
STEP 8D
STEP 9D – Regenerations, total number since start-up: This display shows the total number of
regenerations that have occurred since startup. Press the NEXT button to exit Diagnostics. Press
REGEN to return to previous step.
STEP 9D
RETURN TO NORMAL MODE