OPERATION & MAINTENANCE
INSTRUCTIONS
LS1216
Original Instructions
AIR COMPRESSOR
ELECTRIC MOTOR DRIVEN

Other manuals for Clarke PE16C50

Questions and Answers

  • N
    Natalie GarciaSep 8, 2025
    What causes condensation in crank case of Clarke PE16C50 Air Compressor?
    • M
      munozginaSep 8, 2025
      Condensation in the crankcase of your Clarke Air Compressor, especially in 2-stage compressors, can be caused by the compressor being over-dimensioned. This means operational periods are too short relative to resting periods. Try frequent oil changes and reduce cooling of crankcase.
  • K
    Katherine LewisSep 10, 2025
    Why is my Clarke Air Compressor electric motor too hot?
    • J
      Joshua BakerSep 10, 2025
      If your Clarke Air Compressor's electric motor is too hot, ensure that the operational voltage is not too low (call an electrician) and that the cooling fins of the electric motor are not blocked by dirt (clean the cooling fins).
  • S
    Sara JohnsonSep 12, 2025
    What causes condensation at outlet points of Clarke PE16C50 Air Compressor?
    • A
      Angela StewartSep 12, 2025
      Condensation at the outlet points of your Clarke Air Compressor can be caused by: * Incorrect piping installation: Consult your local dealer. * Compressor taking in air that is too warm: Obtain a better fresh air supply for the compressor. * Delivery temperature of air from air receiver is too high: Use a larger air receiver.
  • M
    Melissa WhiteSep 13, 2025
    Why bleed valve under pressure switch blows whilst Clarke PE16C50 is running?
    • M
      michael97Sep 13, 2025
      If the bleed valve under the pressure switch blows while your Clarke Air Compressor is running, it could be due to a leaking relief valve. Clean the relief valve or change the pressure switch.
  • N
    Nicole FosterSep 15, 2025
    Why bleed valve under pressure switch blows whilst Clarke PE16C50 is not running?
    • W
      Wendy KennedySep 16, 2025
      If the bleed valve under the pressure switch blows while your Clarke Air Compressor is not running, it is likely due to a leaking non-return valve. Clean or replace the non-return valve.
  • J
    Jose MorrisSep 18, 2025
    Why Machine running but not pumping air into the receiver (10HP only) Clarke PE16C50 Air Compressor?
    • A
      Anna ThomasSep 18, 2025
      If the machine is running but not pumping air into the receiver (10HP only), and air is exhausting from the solenoid after the starter has changed direction from star to delta, check the solenoid valve.

Summary

SAFETY PRECAUTIONS

General Safety Rules

Lists critical safety guidelines for operating the compressor.

INSTALLATION

ELECTRICAL CONNECTIONS

BEFORE STARTING COMPRESSOR, CHECK:-

Pre-Start Checks and Warnings

Details essential checks before starting and critical warnings for compressor operation.

TO START COMPRESSOR

TO STOP COMPRESSOR

OUTLET PRESSURE ADJUSTMENTS

TROUBLESHOOTING CHART

Troubleshooting Common Issues

Provides solutions for common compressor problems like not starting or faulty valves.

Troubleshooting Performance Issues

Addresses issues like stopping after a few revolutions, blowing fuses, and noise.

Troubleshooting Operational Issues

Covers continuous running, frequent starting/stopping, and no air delivery.

Troubleshooting Temperature and Oil Issues

Addresses overheating, oil in air delivery, and condensation problems.

TORQUE VALUES FOR CYLINDER HEAD BOLTS

MAINTENANCE CHART

Scheduled Maintenance Tasks

Outlines daily, weekly, and 6-monthly maintenance checks and replacements.

Clarke PE16C50 Specifications

General IconGeneral
BrandClarke
ModelPE16C50
CategoryAir Compressor
LanguageEnglish

Related product manuals