19
(4) Too much abrasive comes
out of nozzle.
Abrasive metering valve too
much opened.
Check and correct adjustments.
Choke valve not completely
opened.
Check and open it completely if
necessary.
(5) Pop-up valve does not
remain closed.
Insufficient air volume or
pressure.
Check air pressure of
compressor with a needle
gauge.
(6) Pop-up valve does not seal
off filling port after
pressurization.
Worn pop-up valve and / or
gasket (item 10).
Replace pop-up valve and / or
gasket.
Blocked guide for pop-up valve. Open inspection door (item 21)
and clean blast machine.
(7) Blast machine does not
depressurize or is blocked.
Clogged deadman handle. Clean deadman handle.
Remote control hose incorrectly
connected.
Exchange connections.
Remote control valve RMS-
2000A (RMS 1500+500) or
RMM-50A defective.
Disassemble and repair it.
Electric remote controls (with or
without dual function):
Switch on the magnetic valve in
position 1“ (manual control).
Put switch in position 0“
(automatic control).