Table of Contents

Questions and Answers

  • M
    michaelharperSep 9, 2025
    What to do if no air and media comes out of Clemco BNP nozzle?
    • S
      Samuel HollowaySep 9, 2025
      If no air and media are coming out of the nozzle of your Clemco Industrial Equipment, make sure the door interlocks are actuated. If a foot pedal was newly installed, ensure the pneumatic hoses are connected properly. A polluted or blocked moisture separator can also cause this issue, so cleanse it. Finally, check the control lines for leaks, which may require a second person to assist.
  • G
    Gina StoneAug 23, 2025
    What to do if no air and media comes out of the Clemco BNP nozzle?
    • J
      John HartAug 23, 2025
      If no air and media are coming out of the nozzle of your Clemco Industrial Equipment, the door interlocks may not be actuated. Adjust the pin or door fixing. If the foot pedal was newly installed, check for wrong connections of pneumatic hoses on the foot pedal, which can cause permanent air blow off, and connect them properly. A polluted moisture separator can also cause this issue; cleanse the moisture separator. Additionally, check the control lines for leaks, which may require a second person to check for leakages while the first person is blasting.
  • V
    valerie57Aug 25, 2025
    Why is there abnormally high media consumption in Clemco Industrial Equipment?
    • B
      Beth Ortega DVMAug 25, 2025
      Abnormally high media consumption in Clemco Industrial Equipment can be caused by an open or leaky cyclone door. Replace the gasket to resolve this. Using media that is too fine or lightweight can also lead to high consumption; install and adjust a supplementary Vortex cylinder. High negative pressure can also be a factor.
  • J
    Joseph HamptonAug 26, 2025
    How to improve the cleaning rate of Clemco BNP?
    • K
      Katherine RushAug 27, 2025
      If your Clemco Industrial Equipment has a poor cleaning rate, first check if there is enough blast media in the circuit and refill if necessary. The media metering valve may be adjusted incorrectly, requiring a new adjustment. Reduced air pressure can also cause a poor cleaning rate; check the air supply, and if the static pressure decreases during blasting, inspect the moisture separator, pressure regulator, and nozzle. A blocked blast hose or gun/nozzle can also cause this; push the nozzle against an elastic object and step on the foot pedal, or disassemble the hose or gun and cleanse, searching for the cause of blockage such as a missing or overfilled screen in the reclaimer.
  • M
    Melissa ValdezAug 27, 2025
    Why does dust come out of the Clemco BNP blower?
    • M
      Mrs. Jessica RomeroAug 27, 2025
      If dust comes out of the blower of your Clemco Industrial Equipment, it could be due to a defective dust filter gasket. Replace the gasket. Alternatively, the cartridge itself may be defective, requiring replacement.
  • A
    Anna HowardAug 29, 2025
    Why is there only air and no media coming out of the Clemco Industrial Equipment nozzle?
    • S
      Sabrina ParksAug 29, 2025
      If air comes out of the nozzle of your Clemco Industrial Equipment but no media, first check if there is blast media in the blast circuit and refill if necessary. The media may also be moist. Remove the moist media and eliminate the cause of humid air supply.
  • J
    jennifer07Sep 18, 2025
    What to do if Clemco Industrial Equipment has irregular flow of blast media?
    • U
      umarquezSep 18, 2025
      If your Clemco Industrial Equipment has an irregular flow or too much blast media coming out of the nozzle, the media flow may be incorrectly adjusted. You will need to adjust it.
  • P
    Patricia StarkSep 19, 2025
    What to do if Clemco BNP Industrial Equipment blast process won't interrupt when foot pedal is released?
    • X
      xphillipsSep 22, 2025
      If the blast process of your Clemco Industrial Equipment doesn't interrupt when the foot pedal is released, the foot pedal valve may be blocked. Depressurize the installation and replace the foot pedal valve.
  • A
    angelagarciaSep 7, 2025
    Why Clemco BNP Industrial Equipment has abnormally high media consumption?
    • G
      George BrownSep 8, 2025
      Abnormally high media consumption in Clemco Industrial Equipment can be caused by a cyclone door that is open or leaky, requiring a gasket replacement. It may also be due to using media that is too fine or lightweight; in this case, install and adjust a supplementary Vortex cylinder.
  • J
    Jay PerkinsSep 4, 2025
    Why does media remain in the suction hose of my Clemco BNP Industrial Equipment?
    • J
      Jamie MillerSep 4, 2025
      Media remaining in the suction hose of Clemco Industrial Equipment can be due to incorrectly adjusted negative pressure. The media may also be too heavy; try using other media.

Summary

3 Product description

3.2 No conventional utilisation - Warnings for misuse

Prohibits specific uses, like in explosion hazard zones or with harmful solvents.

3.3 Operating mode of the complete system

Explains the abrasive circuit flow and pneumatic principles of the system.

4 Set-up for initial installation

4.1 Carriage; Handling

Instructions and diagrams for handling and lifting BNP cabinets.

4.5 Requirements for setting up a cabinet

Specifies space and basic requirements for cabinet installation.

4.6 Installation, assemble and function test

Guides through installation, assembly, and function testing procedures.

5 Operating

5.1 Installation and operation, shut down after work

Steps for installing, operating, and shutting down the blast cabinet.

5.2 Emergency stop

Procedure for using the emergency stop button and its function.

5.4 Special procedures

Covers special procedures and adjustments for the cabinet.

5.4.2 Adjusting BNP gun

Instructions for adjusting the BNP blast gun for optimal performance.

6 Maintenance and cleaning

9 REPLACEMENT PARTS

9.1 Replacement parts BNP 65 and BNP 220

Lists replacement parts for BNP 65 and BNP 220 models with part numbers.

9.2 Replacement parts BNP 601 and 721

Lists replacement parts for BNP 601 and BNP 721 models with part numbers.

Wiring diagram

10 Disposal

Clemco BNP Series Specifications

General IconGeneral
ModelBNP Series
TypePneumatic Blast Nozzle
CapacityVaries by model
Air ConsumptionVaries by model
MaterialTungsten Carbide, Boron Carbide, or Ceramic
Bore SizeVaries by model