Revision: 2.1
Empty dust container (dust
collector).
- Could be necessary already after one hour
Media recovery system
(Reclaimer).
- Empty screen Turn off exhauster. This may be necessary more
often - Screen magnet .
- Check gasket for wear and replace if it’s necessary
6.4 After max. 50 h of blasting
Check and if necessary. replace /cleanse
- Clean filter and sight glass with soap and warm water
(3) Air hoses and blast hoses.
- Gaskets of couplings for wear
- Blast hose by hand for soft spots
6.5 After max. 150 h of blasting
(1) Gasket on cabinet doors.
- See owner manual „ Dust collector“
6.6 After other periodes of time
replace (even without wear) after maximal
Air hoses – external air supply
7 Troubleshooting
Exhaust motor does not rotate.
Slide damper in false position
Blow off filter cartridge.
Replace
Exhaust motor rotates in the
wrong direction.
Reverse polarity (only through licensed electrician).
Blast media breaks down
rapidly and creates dust
- lower blast pressure
- Other media.
Blocked hose between blast
cabinet and reclaimer / cyclone
Check and if necessary disassemble hose and
remove dust and media.
Blockage is not the real cause.
Air leakage in the suction cycle.
Check the following components:
- Reclaimer door open or leaky.
- Test the connections of hose for leaks