5.2 Emergency stop
Push emergency stop
button
Electrical supply is disconnected, dedusting too
-close external air
supply
Depressurize moisture separator over drain screw
Clarification of causation
5.3 Shut down by longer interruption of work or moving the cabinet
Remove media
see 5.4.4.
Disconnect electricity
Authorized electrician
close external air
supply
Depressurize moisture separator over drain screw
5.4 Special procedures
5.4.1 Adjust media / air mixture
Pos.No.:
Description
1
Adjust screw
2
Locking nut
3
Housing
Direction A less media
Direction B more media