5.4.7 Adjust doorsafety interlock
No.:
Description
1
Door safety interlock
2
Nut for screw adjusting
3
Actuating screw for safety interlock
4
Cabinet door
Figure 6: Door safety interlock connection
6 Maintenance and cleaning
6.1 Preface
During operation the cabinets are exposed to wear. In order to ensure safe operation and high efficiency the blast
machines must be maintained regulary.
Warning! Risk of injuri!
Dicharge completely pressure during
maintenance jobs. (see 5.4.1)
6.2 If required
Check and if necessary. replace /cleanse
View window
-Cover lenses
-If necessary window glass – see 5.4.6
Gloves
6.3 After max. 8 h of blasting
Check and if necessary. replace /cleanse
Door interlock
-Open doors
- Press pin (1). It has to return from alone.