Part No. GEMINI-OPM B 7/02
Use and Care Instructions
Dual Gas Steam Generator & Convection Steamer
Series: Gemini Model Nos. 24CGA6.2, 24CGA10.2
1333 East 179
th
Street
Cleveland, Ohio 44110
Phone: (216) 481-4900
Fax: (216) 481 3782
24CGA6.2
24CGA10.2

Table of Contents

Other manuals for Cleveland 24CGA10.2

Questions and Answers

  • J
    Jonathan FordAug 17, 2025
    What to do if the Cleveland 24CGA10.2 Electric Steamer control panel POWER indicator light is ON but the steamer doesn't make steam?
    • L
      Larry TaylorAug 17, 2025
      If the control panel POWER indicator light is ON, but your Cleveland Electric Steamer isn't producing steam in MANUAL or TIMED mode, here's what you can check: * Ensure the water supply valves are open. * Verify the gas supply is turned ON. * Confirm the door is completely closed and the interlock switch is engaged. * Clean the water line strainer and/or external filter system if they're clogged.
  • M
    Mary HarrisAug 20, 2025
    Why won't the power indicator light turn on for my Cleveland 24CGA10.2 Electric Steamer?
    • S
      Shannon MedinaAug 20, 2025
      If the power indicator light on your Cleveland Electric Steamer doesn't turn ON when the ON/OFF lever/switch is in the ON position: * Make sure the power is turned ON at the main external power switch. * Ensure the ON/OFF lever/switch is fully turned to the ON position.
  • E
    Eric OsbornAug 22, 2025
    Why is my Cleveland 24CGA10.2 food taking too long to cook?
    • R
      Randy MilesAug 22, 2025
      If food is taking too long to cook in your Cleveland Electric Steamer, consider the following: * Ensure pans are not too close to the bottom; place them on racks near the top. * Reduce the amount of food in each pan and use fewer pans to avoid overloading the compartment. * Confirm proper connections to avoid hot water in the condenser line. * Descale the steam generator with an approved descaler to remove any scale buildup. * Increase cooking times for frozen food. * Remove coverings from food; steam must have direct access to the food. * Extend cooking times for altitudes above 2500 feet.
  • W
    William DoyleAug 26, 2025
    What to do if there's an abnormal amount of steam coming from the drain of my Cleveland 24CGA10.2 Electric Steamer?
    • A
      andrea67Aug 26, 2025
      If you notice an abnormal amount of steam coming from the drain of your Cleveland Electric Steamer, check these potential causes: * Ensure the water supply to the condenser is turned ON by opening the water supply valve. * Make sure cold water, not hot water, is connected to the condenser fitting. * Clean out the condenser water supply strainer if it's clogged. * Repair or replace the water supply line if it's blocked, broken, or leaking.
  • A
    Alejandro MillerAug 28, 2025
    How to fix reduced steam flow in my Cleveland 24CGA10.2?
    • R
      Rebecca AtkinsAug 28, 2025
      To fix reduced steam flow into the cooking compartment of your Cleveland Electric Steamer: * Descale the steam generator with Cleveland Range approved descaler. * Ensure the gas inlet pressure meets the minimum requirement: 4.5 inches W.C. for Natural gas and 11.0 inches W.C. for propane gas to operate.
  • S
    Sheila SchroederAug 31, 2025
    What to do if my Cleveland 24CGA10.2 is leaking water from the bottom?
    • J
      Jasmine DavisAug 31, 2025
      If you find water leaking from the bottom of your Cleveland Electric Steamer cabinet, turn off electricity at the main power switch and close the water supply valve(s) because it may be caused by broken or loose plumbing inside the steamer cabinet.
  • J
    Joseph AverySep 2, 2025
    Why won't my Cleveland 24CGA10.2 Electric Steamer steam generator fill?
    • C
      Christopher CurtisSep 3, 2025
      If your Cleveland Electric Steamer's steam generator isn't filling, try these solutions: * Open the water supply valves to ensure the water supply to the steamer isn't shut OFF. * Clean the water supply strainer and/or filter system if they are clogged.
  • H
    hchaseSep 5, 2025
    What does it mean when the 'Descale Required' indicator is lit on my Cleveland 24CGA10.2 Electric Steamer?
    • C
      Carl DavisSep 5, 2025
      When the 'Descale Required' indicator is lit on your Cleveland Electric Steamer, it means: * If the unit is new or has just been descaled, press the switch to reset the descale timer. * If the unit needs descaling, descale it with Cleveland Range approved descaler, and then press the switch to reset the timer.
  • A
    Andre JonesSep 8, 2025
    Why does steam and/or water drain around the compartment door of my Cleveland Electric Steamer?
    • D
      David GonzalezSep 8, 2025
      A small amount of water condensing around the door of your Cleveland Electric Steamer is normal. However, if there's excessive draining: * Ensure the compartment drain is not clogged; clean it with a USDA approved drain cleaner. * Verify the external drain is properly installed, free-air vented, and pitched down.
  • J
    Jamie YangSep 12, 2025
    What should I do if abnormal steam comes from drain during the blowdown cycle of my Cleveland 24CGA10.2?
    • S
      Steven CampbellSep 12, 2025
      If you observe an abnormal amount of steam coming from the drain during the blowdown cycle of your Cleveland Electric Steamer, ensure the ON/OFF lever/switch is turned fully to the OFF position to start the proper blowdown operation.

Summary

Chapter 1 Introduction

Gas Leak Instructions

Instructions for responding to suspected gas leaks.

Operational Safety

Essential safety policies for steamer operation.

Chapter 2 General Operation

Chapter 3 Control Panels

Dial Timer Control Panel

Overview of the mechanical dial timer control panel.

Keypad Timer Control Panel

Overview of the electronic keypad timer control panel.

Instant On Control Panel

Details of the control panel for the 'Instant ON' model.

Chapter 4 Cooking With The Steamer

Chapter 5 Shutdown and Cleaning Procedures

Chapter 6 Preventative Maintenance and Troubleshooting

Operators Troubleshooting Guide

Guide to diagnose and resolve common operating issues.

Chapter 7 Steam Cooking Guide

Cleveland 24CGA10.2 Specifications

General IconGeneral
Model24CGA10.2
TypeElectric Steamer
PowerElectric
Description2-Compartment Boilerless Electric Steamer
Compartments2
Water CapacityN/A (Boilerless)
Voltage208-240V
Phase3
Wattage12000 W