Tranquility
®
16
COMPACT (TC) Series
MODELS TCH/V 006 - 60
60 HZ - HFC-410A
INSTALLATION, OPERATION
& MAINTENANCE
97B0075N07
Revised: July 7, 2020
Table of Contents
Model Nomenclature – General Overview 3
General Information 4
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
TC - Horizontal – Dimensional Data 20
TCH with WSE – Dimensional Data 22
TC - Horizontal Service Access 24
TC - Vertical Upow – Dimensional Data 25
TCV with WSE – Dimensional Data 27
TC - Vertical Service Access 29
Electrical Data – Standard Unit 30
Electrical Data – High Static Blower 31
Electrical Data – Constant Torque ECM 32
Electrical Data – Constant Volume ECM 33
Electrical – Line Voltage 34
Eletctical – Power & Low Voltage Wiring 35
Electrical – Low Voltage Wiring 36
Electrical – Thermostat Wiring 37
Blower Performance Data – TC006 38
Blower Performance Data – TC009 39
Blower Performance Data – TC012 40
Blower Performance Data – TC015 41
Blower Performance Data – TC018 42
Blower Performance Data – TC024 43
Blower Performance Data – TC030 44
Blower Performance Data – TC036 45
Blower Performance Data – TC041 46
Blower Performance Data – TC042 47
Blower Performance Data – TC048 48
Blower Performance Data – TC060 49
Constant Volume ECM Control 50
Wiring Diagram Matrix 52
DIP Setting Table 53
CXM Controls 54
DXM2 Controls 55
Safety Features – CXM and DXM2 Controls 60
Unit Starting and Operating Conditions 62
Piping System Cleaning and Flushing 63
TC with Waterside Economizer Option 64

Table of Contents

Questions and Answers

  • M
    Matthew JohnsonAug 18, 2025
    How to troubleshoot main power problems in my ClimateMaster Tranquility TCV 041?
    • J
      Jason Jones Jr.Aug 18, 2025
      If the green status LED is off on your ClimateMaster Heat Pump, start by checking the line voltage circuit breaker and disconnect. Also, check for line voltage between L1 and L2 on the contactor. Further, verify that there is 24VAC between R and C on CXM/DXM2. Finally, examine the primary and secondary voltage on the transformer.
  • C
    Connie StoneAug 23, 2025
    What causes LP/LOC Fault Code 3 (Low Pressure / Loss of Charge) in a ClimateMaster Heat Pump?
    • T
      thomas56Aug 23, 2025
      If your ClimateMaster Heat Pump shows a Low Pressure/Loss of Charge fault (Code 3), it might be due to insufficient charge. Check for refrigerant leaks. Also, check the charge and start-up water flow.
  • J
    Jonathan AndersenAug 26, 2025
    Why does my ClimateMaster Tranquility TCV 041 Heat Pump show LT1 Fault Code 4 (Water coil low temperature limit)?
    • B
      Brianna SmithAug 26, 2025
      If your ClimateMaster Heat Pump displays a Water coil low temperature limit fault (LT1 Fault Code 4), it could be due to several reasons. Start by checking the pump operation or water valve operation/setting if there is reduced or no water flow in heating. Clean or replace the plugged strainer or filter. Ensure the water flow is adjusted to the proper rate. Check the antifreeze density with a hydrometer to ensure an adequate level. If using antifreeze, clip the JW3 jumper for antifreeze (10°F [-12°C]) use. Ensure the water temperature is within design parameters. Finally, check the thermistor's temperature and impedance correlation per the chart; replace if it's bad.
  • D
    Diane WilliamsAug 27, 2025
    What does LT2 Fault Code 5 (Air coil low temperature limit) mean on my ClimateMaster Heat Pump?
    • C
      Charles EllisonAug 27, 2025
      If your ClimateMaster Heat Pump is showing an Air coil low temperature limit fault (LT2 Fault Code 5), it could be due to several reasons. First, check for a dirty air filter and clean or replace it if there is reduced or no air flow in cooling. Check the fan motor operation and airflow restrictions. Check the static pressure against the blower table if the external static is too high. Ensure the entering air temperature is within design parameters. If the temperature limit setting is improper (30°F vs 10°F [-1°C vs -12°C]), normal airside applications will require 30°F [-1°C] only. Finally, check the thermistor's temperature and impedance correlation per the chart if it's bad.
  • J
    Joseph GuerreroAug 30, 2025
    How do I fix Condensate Fault Code 6 on my ClimateMaster Tranquility TCV 041?
    • P
      plambAug 30, 2025
      If your ClimateMaster Heat Pump displays Condensate Fault Code 6, it could be caused by a blocked drain. Check for blockage and clean the drain. Inspect the trap dimensions and ensure its location is ahead of the vent. Check for proper piping slope away from the unit to ensure good drainage. Ensure the unit slopes toward the outlet. Check the vent location for poor venting. Check for moisture shorting to the air coil if there's moisture on the sensor. Replace the air filter if it is plugged. Find and eliminate any restrictions to return airflow, and consider increasing the return duct and/or grille size.
  • S
    Stephanie WilliamsSep 1, 2025
    What does Over/Under Voltage Code 7 mean for my ClimateMaster Tranquility TCV 041 Heat Pump?
    • R
      Renee McgrathSep 1, 2025
      If your ClimateMaster Heat Pump is showing Over/Under Voltage Code 7 (Auto resetting), it may be due to under voltage. Check the power supply and 24VAC voltage before and during operation. Also, check the power supply wire size. Check compressor starting and consider if a hard start kit is needed. Verify the 24VAC and unit transformer tap for correct power supply voltage. If it is due to over voltage, check the power supply voltage and 24VAC before and during operation. Also, check the 24VAC and unit transformer tap for correct power supply voltage.
  • T
    Troy CampbellSep 3, 2025
    What does Unit Performance Sentinel Code 8 mean on my ClimateMaster Heat Pump?
    • T
      Taylor WilsonSep 3, 2025
      If your ClimateMaster Heat Pump displays Unit Performance Sentinel Code 8, it could be due to the following reasons. In heating mode, if LT2 is greater than 125°F [52°C], check for poor airflow or an overcharged unit. In cooling mode, if LT1 is greater than 125°F [52°C] or LT2 is less than 40ºF [4ºC], check for poor water flow or airflow.
  • R
    Robert RamirezSep 6, 2025
    Why is my ClimateMaster Heat Pump short cycling?
    • A
      ashleybushSep 6, 2025
      If your ClimateMaster Heat Pump is short cycling, it could be due to a dirty air filter; check and clean the air filter. The unit might be in 'test mode'; reset power or wait 20 minutes for auto exit. The unit may be oversized for the space; check the sizing for the actual load of the space. Check the compressor overload and replace if necessary.
  • J
    jasonallenSep 8, 2025
    What causes only the fan to run on my ClimateMaster Tranquility TCV 041?
    • E
      Elijah CrosbySep 8, 2025
      If only the fan is running on your ClimateMaster Heat Pump, ensure the thermostat is set for heating or cooling operation. Check for lockout codes and reset power if necessary. Inspect the compressor overload and replace if needed. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode.
  • N
    nburchSep 10, 2025
    Why does only the compressor run on my ClimateMaster Tranquility TCV 041?
    • C
      Curtis ThomasSep 12, 2025
      If only the compressor runs on your ClimateMaster Heat Pump, check the G wiring at the heat pump. Jumper G and R for fan operation. Check the fan motor relay by jumpering G and R for fan operation and check for Line voltage across BR contacts. Check the fan power enable relay operation (if present). Check for line voltage at the motor and inspect the capacitor. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode. Set for cooling demand and check 24VAC on RV coil and at CXM/DXM2 board for the reversing valve. Check for ‘O’ RV setup not ‘B’ for thermostat setup. Check O wiring at heat pump and jumper O and R for RV coil ‘click’.

Summary

Model Nomenclature - General Overview

Supply Air Options

Details various supply air configurations, motor types, and their corresponding unit types.

General Information

Safety Precautions and Warnings

Details DANGER, WARNING, CAUTION, and NOTICE statements for safe operation.

Horizontal Installation

Horizontal Unit Location Considerations

Specifies requirements for selecting an appropriate indoor location for horizontal units.

Vertical Installation

Vertical Unit Location Considerations

Specifies requirements for selecting an appropriate indoor location for vertical units.

Piping Installation Guidelines

Supply and Return Piping Installation Procedures

Covers general guidelines for connecting water piping, including hose kits and bend radii.

Ground-Loop Heat Pump Applications

Ground Loop Pre-Installation and Piping Requirements

Covers site preparation, piping materials, and testing for ground loops.

Ground-Water Heat Pump Applications

Open Loop Ground Water System Piping

Discusses piping materials, valves, and P/T plugs for open loop systems.

Water Quality Standards and Heat Exchanger Selection

Guides on assessing water quality and choosing appropriate heat exchangers.

Water Quality Standards

TC Vertical Service Access

Left Return Vertical Unit Service Access

Illustrates service access points and required clearances for left return vertical units.

Right Return Vertical Unit Service Access

Illustrates service access points and required clearances for right return vertical units.

Electrical Data - Standard Unit

Electrical Data - High Static Blower

Electrical Data - Constant Torque ECM

Electrical Data - Constant Volume ECM

Electrical - Line Voltage Wiring

General Line Voltage Wiring Practices

Covers field wiring compliance, voltage checks, and conduit usage for safety.

Electrical - Power and Low Voltage Wiring

Low Voltage Wiring for Thermostat Connections

Details thermostat connections to CXM or DXM2 control boards for proper operation.

Electrical - Thermostat Wiring

Blower Performance Data - TC006

Blower Performance Data - TC009

Blower Performance Data - TC012

Blower Performance Data - TC015

Blower Performance Data - TC018

Blower Performance Data - TC024

Blower Performance Data - TC030

Blower Performance Data - TC036

Blower Performance Data - TC041

Blower Performance Data - TC042

Blower Performance Data - TC048

Blower Performance Data - TC060

Constant Volume ECM Control

TC Series Wiring Diagram Matrix

DIP Setting Table

CXM Controls

CXM Control Features and Test Mode Operation

Describes test mode, retry mode, and various field configuration options for CXM controls.

DXM2 Controls

DXM2 Control Features and Test Mode Operation

Describes test mode, retry mode, and field configuration options for DXM2 controls.

DXM2 Controls Continued

DXM2 Thermostat Details

Safety Features - CXM and DXM2 Controls

Compressor Safety Protections and Lockout Codes

Details features like anti-short cycle, random start, pressure switches, and lockout codes.

Temperature Limit Safety Features

Explains protections related to water coil (LT1) and air coil (LT2) temperatures and their faults.

Safety Features - CXM and DXM2 Controls Continued

Unit Starting and Operating Conditions

Piping System Cleaning and Flushing

TC with Waterside Economizer Option

Unit and System Checkout

Unit Checkout Procedures Checklist

Lists essential checks to perform on the unit itself before powering up the system.

System Checkout Procedures Checklist

Lists essential checks to perform on the overall system before powering up.

Unit Start-up Procedure

Cooling Mode Start-up Steps and Checks

Details the sequence for testing the unit in cooling mode, including temperature and pressure checks.

Heating Mode Start-up Steps and Checks

Details the sequence for testing the unit in heating mode, including temperature and pressure checks.

Unit Operating Conditions

Preventive Maintenance Procedures

Water Coil Maintenance Guidelines

Details maintenance for both direct ground water and other loop applications, including scaling prevention.

Functional Troubleshooting Guide

Main Power and Control Board Fault Diagnosis

Addresses issues related to power, status LEDs, and control board faults with solutions.

Pressure and Temperature Limit Fault Diagnosis

Details troubleshooting for high/low pressure, LT1/LT2 faults, and condensate overflow.

Voltage, Sentinel, and Thermistor Fault Diagnosis

Covers over/under voltage, UPS, swapped thermistors, and unit short cycling.

Performance Troubleshooting Guide

Insufficient Capacity Troubleshooting Steps

Addresses causes of low cooling or heating capacity, like dirty filters or leaks.

High Head Pressure Troubleshooting Steps

Covers causes of high head pressure, such as restricted airflow or overcharging.

Low Suction Pressure Troubleshooting Steps

Details troubleshooting for low suction pressure, including refrigerant charge and water flow.

Start-Up Log Sheet

Functional Troubleshooting Analysis Tools

Warranty Information (U.S. & Canada)

Warranty Information (International)

ClimateMaster Tranquility TCV 041 Specifications

General IconGeneral
ModelTCV041
CategoryHeat Pump
RefrigerantR-410A
Phase1
Compressor TypeScroll
Max Water Flow Rate12 GPM
Cooling Capacity48, 000 BTU/h
Heating Capacity48, 000 BTU/hr
Voltage208/230V

Related product manuals