Tranquility
®
16
COMPACT (TC) Series
MODELS TCH/V 006 - 60
60 HZ - HFC-410A
INSTALLATION, OPERATION
& MAINTENANCE
97B0075N07
Revised: July 7, 2020
Table of Contents
Model Nomenclature – General Overview 3
General Information 4
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
TC - Horizontal – Dimensional Data 20
TCH with WSE – Dimensional Data 22
TC - Horizontal Service Access 24
TC - Vertical Upow – Dimensional Data 25
TCV with WSE – Dimensional Data 27
TC - Vertical Service Access 29
Electrical Data – Standard Unit 30
Electrical Data – High Static Blower 31
Electrical Data – Constant Torque ECM 32
Electrical Data – Constant Volume ECM 33
Electrical – Line Voltage 34
Eletctical – Power & Low Voltage Wiring 35
Electrical – Low Voltage Wiring 36
Electrical – Thermostat Wiring 37
Blower Performance Data – TC006 38
Blower Performance Data – TC009 39
Blower Performance Data – TC012 40
Blower Performance Data – TC015 41
Blower Performance Data – TC018 42
Blower Performance Data – TC024 43
Blower Performance Data – TC030 44
Blower Performance Data – TC036 45
Blower Performance Data – TC041 46
Blower Performance Data – TC042 47
Blower Performance Data – TC048 48
Blower Performance Data – TC060 49
Constant Volume ECM Control 50
Wiring Diagram Matrix 52
DIP Setting Table 53
CXM Controls 54
DXM2 Controls 55
Safety Features – CXM and DXM2 Controls 60
Unit Starting and Operating Conditions 62
Piping System Cleaning and Flushing 63
TC with Waterside Economizer Option 64

Table of Contents

Questions and Answers

  • L
    Lisa WatkinsAug 18, 2025
    How to troubleshoot main power problems in my ClimateMaster Heat Pump?
    • P
      Peggy AlvaradoAug 18, 2025
      If the green status LED is off on your ClimateMaster Heat Pump, start by checking the line voltage circuit breaker and disconnect. Also, check for line voltage between L1 and L2 on the contactor. Further, verify that there is 24VAC between R and C on CXM/DXM2. Finally, examine the primary and secondary voltage on the transformer.
  • H
    Heather PetersonAug 23, 2025
    What causes LP/LOC Fault Code 3 (Low Pressure / Loss of Charge) in a ClimateMaster Tranquility TCH 036 Heat Pump?
    • J
      Jeremy TorresAug 23, 2025
      If your ClimateMaster Heat Pump shows a Low Pressure/Loss of Charge fault (Code 3), it might be due to insufficient charge. Check for refrigerant leaks. Also, check the charge and start-up water flow.
  • V
    Vanessa JohnstonAug 26, 2025
    Why does my ClimateMaster Heat Pump show LT1 Fault Code 4 (Water coil low temperature limit)?
    • T
      Travis HaleAug 26, 2025
      If your ClimateMaster Heat Pump displays a Water coil low temperature limit fault (LT1 Fault Code 4), it could be due to several reasons. Start by checking the pump operation or water valve operation/setting if there is reduced or no water flow in heating. Clean or replace the plugged strainer or filter. Ensure the water flow is adjusted to the proper rate. Check the antifreeze density with a hydrometer to ensure an adequate level. If using antifreeze, clip the JW3 jumper for antifreeze (10°F [-12°C]) use. Ensure the water temperature is within design parameters. Finally, check the thermistor's temperature and impedance correlation per the chart; replace if it's bad.
  • J
    John SimsAug 27, 2025
    What does LT2 Fault Code 5 (Air coil low temperature limit) mean on my ClimateMaster Tranquility TCH 036 Heat Pump?
    • P
      piercemichelleAug 27, 2025
      If your ClimateMaster Heat Pump is showing an Air coil low temperature limit fault (LT2 Fault Code 5), it could be due to several reasons. First, check for a dirty air filter and clean or replace it if there is reduced or no air flow in cooling. Check the fan motor operation and airflow restrictions. Check the static pressure against the blower table if the external static is too high. Ensure the entering air temperature is within design parameters. If the temperature limit setting is improper (30°F vs 10°F [-1°C vs -12°C]), normal airside applications will require 30°F [-1°C] only. Finally, check the thermistor's temperature and impedance correlation per the chart if it's bad.
  • S
    steven44Aug 30, 2025
    How do I fix Condensate Fault Code 6 on my ClimateMaster Tranquility TCH 036?
    • J
      John ButlerAug 30, 2025
      If your ClimateMaster Heat Pump displays Condensate Fault Code 6, it could be caused by a blocked drain. Check for blockage and clean the drain. Inspect the trap dimensions and ensure its location is ahead of the vent. Check for proper piping slope away from the unit to ensure good drainage. Ensure the unit slopes toward the outlet. Check the vent location for poor venting. Check for moisture shorting to the air coil if there's moisture on the sensor. Replace the air filter if it is plugged. Find and eliminate any restrictions to return airflow, and consider increasing the return duct and/or grille size.
  • R
    Ricky ParkerSep 1, 2025
    What does Over/Under Voltage Code 7 mean for my ClimateMaster Heat Pump?
    • J
      James FisherSep 1, 2025
      If your ClimateMaster Heat Pump is showing Over/Under Voltage Code 7 (Auto resetting), it may be due to under voltage. Check the power supply and 24VAC voltage before and during operation. Also, check the power supply wire size. Check compressor starting and consider if a hard start kit is needed. Verify the 24VAC and unit transformer tap for correct power supply voltage. If it is due to over voltage, check the power supply voltage and 24VAC before and during operation. Also, check the 24VAC and unit transformer tap for correct power supply voltage.
  • D
    David ButlerSep 3, 2025
    What does Unit Performance Sentinel Code 8 mean on my ClimateMaster Tranquility TCH 036?
    • M
      Monique ThorntonSep 3, 2025
      If your ClimateMaster Heat Pump displays Unit Performance Sentinel Code 8, it could be due to the following reasons. In heating mode, if LT2 is greater than 125°F [52°C], check for poor airflow or an overcharged unit. In cooling mode, if LT1 is greater than 125°F [52°C] or LT2 is less than 40ºF [4ºC], check for poor water flow or airflow.
  • S
    Stephen JohnsonSep 5, 2025
    Why is my ClimateMaster Tranquility TCH 036 short cycling?
    • J
      Jeffrey VasquezSep 5, 2025
      If your ClimateMaster Heat Pump is short cycling, it could be due to a dirty air filter; check and clean the air filter. The unit might be in 'test mode'; reset power or wait 20 minutes for auto exit. The unit may be oversized for the space; check the sizing for the actual load of the space. Check the compressor overload and replace if necessary.
  • K
    Kayla CarterSep 8, 2025
    What causes only the fan to run on my ClimateMaster Heat Pump?
    • D
      Darius RoweSep 8, 2025
      If only the fan is running on your ClimateMaster Heat Pump, ensure the thermostat is set for heating or cooling operation. Check for lockout codes and reset power if necessary. Inspect the compressor overload and replace if needed. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode.
  • C
    Chelsea JohnsonSep 10, 2025
    Why does only the compressor run on my ClimateMaster Tranquility TCH 036 Heat Pump?
    • D
      denise27Sep 12, 2025
      If only the compressor runs on your ClimateMaster Heat Pump, check the G wiring at the heat pump. Jumper G and R for fan operation. Check the fan motor relay by jumpering G and R for fan operation and check for Line voltage across BR contacts. Check the fan power enable relay operation (if present). Check for line voltage at the motor and inspect the capacitor. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode. Set for cooling demand and check 24VAC on RV coil and at CXM/DXM2 board for the reversing valve. Check for ‘O’ RV setup not ‘B’ for thermostat setup. Check O wiring at heat pump and jumper O and R for RV coil ‘click’.

Summary

Model Nomenclature

General Overview

Explains the model nomenclature system and general unit features.

General Information and Safety

Safety Warnings and Precautions

Details safety hazards (Danger, Warning, Caution) and general warnings.

Unit Inspection, Storage, and Protection

Guidelines for inspection, storage, and job site protection of units.

Installation Procedures

Horizontal Installation

Covers location, mounting, suspension, and air discharge conversion.

Vertical Installation

Guidelines for locating, mounting, and sound attenuation of vertical units.

Piping Installation

Procedures for connecting supply and return water piping.

System Applications and Water Quality

Water-Loop Heat Pump Applications

Discusses commercial water loop system setup and requirements.

Ground-Loop and Ground-Water Applications

Details installation practices for ground-source systems and water quality.

Water Quality Standards

Provides guidelines for evaluating water quality parameters.

Dimensional Data and Service Access

Horizontal Unit Dimensions

Provides cabinet and connection dimensions for horizontal units.

Vertical Unit Dimensions

Offers cabinet and connection dimensions for vertical units.

Service Access Requirements

Illustrates required service access points for horizontal and vertical units.

Electrical and Control Systems

Electrical Data

Presents detailed electrical specifications for various unit configurations.

Wiring and Connections

Covers line voltage, low voltage, and thermostat wiring guidelines.

Control System Operation

Explains CXM and DXM2 controls, DIP settings, and safety features.

Blower Performance Data

Blower Performance Tables

Provides detailed airflow and static pressure performance data for various models.

Operation, Maintenance, and Troubleshooting

Unit Starting and Operating Conditions

Specifies operating limits and starting conditions for proper unit function.

Preventive Maintenance

Outlines recommended maintenance schedules for unit components.

Troubleshooting Guides

Provides guidance for diagnosing and resolving operational faults.

Warranty Information

U.S. & Canada Warranty

Details the limited express warranty terms for North America.

International Warranty

Outlines warranty terms for products sold outside the US and Canada.

Revision History

Document Revision Log

Lists changes and updates made to the manual over time.

ClimateMaster Tranquility TCH 036 Specifications

General IconGeneral
ModelTranquility TCH036
CategoryHeat Pump
Cooling Capacity (BTU/h)36, 000
Cooling Capacity (tons)3
RefrigerantR-410A
Voltage (VAC)208-230
Phase1
Compressor TypeScroll