Tranquility
®
16
COMPACT (TC) Series
MODELS TCH/V 006 - 60
60 HZ - HFC-410A
INSTALLATION, OPERATION
& MAINTENANCE
97B0075N07
Revised: July 7, 2020
Table of Contents
Model Nomenclature – General Overview 3
General Information 4
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
TC - Horizontal – Dimensional Data 20
TCH with WSE – Dimensional Data 22
TC - Horizontal Service Access 24
TC - Vertical Upow – Dimensional Data 25
TCV with WSE – Dimensional Data 27
TC - Vertical Service Access 29
Electrical Data – Standard Unit 30
Electrical Data – High Static Blower 31
Electrical Data – Constant Torque ECM 32
Electrical Data – Constant Volume ECM 33
Electrical – Line Voltage 34
Eletctical – Power & Low Voltage Wiring 35
Electrical – Low Voltage Wiring 36
Electrical – Thermostat Wiring 37
Blower Performance Data – TC006 38
Blower Performance Data – TC009 39
Blower Performance Data – TC012 40
Blower Performance Data – TC015 41
Blower Performance Data – TC018 42
Blower Performance Data – TC024 43
Blower Performance Data – TC030 44
Blower Performance Data – TC036 45
Blower Performance Data – TC041 46
Blower Performance Data – TC042 47
Blower Performance Data – TC048 48
Blower Performance Data – TC060 49
Constant Volume ECM Control 50
Wiring Diagram Matrix 52
DIP Setting Table 53
CXM Controls 54
DXM2 Controls 55
Safety Features – CXM and DXM2 Controls 60
Unit Starting and Operating Conditions 62
Piping System Cleaning and Flushing 63
TC with Waterside Economizer Option 64

Table of Contents

Questions and Answers

  • J
    Justin AllenAug 18, 2025
    How to troubleshoot main power problems in my ClimateMaster Tranquility TCH 048?
    • J
      Jennifer ChristianAug 18, 2025
      If the green status LED is off on your ClimateMaster Heat Pump, start by checking the line voltage circuit breaker and disconnect. Also, check for line voltage between L1 and L2 on the contactor. Further, verify that there is 24VAC between R and C on CXM/DXM2. Finally, examine the primary and secondary voltage on the transformer.
  • W
    William GarciaAug 23, 2025
    What causes LP/LOC Fault Code 3 (Low Pressure / Loss of Charge) in a ClimateMaster Tranquility TCH 048 Heat Pump?
    • M
      Marilyn RamirezAug 23, 2025
      If your ClimateMaster Heat Pump shows a Low Pressure/Loss of Charge fault (Code 3), it might be due to insufficient charge. Check for refrigerant leaks. Also, check the charge and start-up water flow.
  • A
    alejandromartinezAug 25, 2025
    Why does my ClimateMaster Tranquility TCH 048 Heat Pump show LT1 Fault Code 4 (Water coil low temperature limit)?
    • J
      Jason RossAug 26, 2025
      If your ClimateMaster Heat Pump displays a Water coil low temperature limit fault (LT1 Fault Code 4), it could be due to several reasons. Start by checking the pump operation or water valve operation/setting if there is reduced or no water flow in heating. Clean or replace the plugged strainer or filter. Ensure the water flow is adjusted to the proper rate. Check the antifreeze density with a hydrometer to ensure an adequate level. If using antifreeze, clip the JW3 jumper for antifreeze (10°F [-12°C]) use. Ensure the water temperature is within design parameters. Finally, check the thermistor's temperature and impedance correlation per the chart; replace if it's bad.
  • H
    henry03Aug 27, 2025
    What does LT2 Fault Code 5 (Air coil low temperature limit) mean on my ClimateMaster Heat Pump?
    • H
      Hannah BaileyAug 27, 2025
      If your ClimateMaster Heat Pump is showing an Air coil low temperature limit fault (LT2 Fault Code 5), it could be due to several reasons. First, check for a dirty air filter and clean or replace it if there is reduced or no air flow in cooling. Check the fan motor operation and airflow restrictions. Check the static pressure against the blower table if the external static is too high. Ensure the entering air temperature is within design parameters. If the temperature limit setting is improper (30°F vs 10°F [-1°C vs -12°C]), normal airside applications will require 30°F [-1°C] only. Finally, check the thermistor's temperature and impedance correlation per the chart if it's bad.
  • M
    millerterryAug 29, 2025
    How do I fix Condensate Fault Code 6 on my ClimateMaster Tranquility TCH 048 Heat Pump?
    • R
      robert57Aug 30, 2025
      If your ClimateMaster Heat Pump displays Condensate Fault Code 6, it could be caused by a blocked drain. Check for blockage and clean the drain. Inspect the trap dimensions and ensure its location is ahead of the vent. Check for proper piping slope away from the unit to ensure good drainage. Ensure the unit slopes toward the outlet. Check the vent location for poor venting. Check for moisture shorting to the air coil if there's moisture on the sensor. Replace the air filter if it is plugged. Find and eliminate any restrictions to return airflow, and consider increasing the return duct and/or grille size.
  • V
    Victoria WiseSep 1, 2025
    What does Over/Under Voltage Code 7 mean for my ClimateMaster Tranquility TCH 048 Heat Pump?
    • R
      Richard ElliottSep 1, 2025
      If your ClimateMaster Heat Pump is showing Over/Under Voltage Code 7 (Auto resetting), it may be due to under voltage. Check the power supply and 24VAC voltage before and during operation. Also, check the power supply wire size. Check compressor starting and consider if a hard start kit is needed. Verify the 24VAC and unit transformer tap for correct power supply voltage. If it is due to over voltage, check the power supply voltage and 24VAC before and during operation. Also, check the 24VAC and unit transformer tap for correct power supply voltage.
  • M
    Michelle SchwartzSep 3, 2025
    What does Unit Performance Sentinel Code 8 mean on my ClimateMaster Tranquility TCH 048 Heat Pump?
    • M
      Mrs. Samantha ReyesSep 3, 2025
      If your ClimateMaster Heat Pump displays Unit Performance Sentinel Code 8, it could be due to the following reasons. In heating mode, if LT2 is greater than 125°F [52°C], check for poor airflow or an overcharged unit. In cooling mode, if LT1 is greater than 125°F [52°C] or LT2 is less than 40ºF [4ºC], check for poor water flow or airflow.
  • W
    williamsjasonSep 5, 2025
    Why is my ClimateMaster Tranquility TCH 048 Heat Pump short cycling?
    • T
      Todd LaneSep 5, 2025
      If your ClimateMaster Heat Pump is short cycling, it could be due to a dirty air filter; check and clean the air filter. The unit might be in 'test mode'; reset power or wait 20 minutes for auto exit. The unit may be oversized for the space; check the sizing for the actual load of the space. Check the compressor overload and replace if necessary.
  • O
    odrakeSep 8, 2025
    What causes only the fan to run on my ClimateMaster Tranquility TCH 048 Heat Pump?
    • L
      linerinSep 8, 2025
      If only the fan is running on your ClimateMaster Heat Pump, ensure the thermostat is set for heating or cooling operation. Check for lockout codes and reset power if necessary. Inspect the compressor overload and replace if needed. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode.
  • C
    Craig LangSep 12, 2025
    Why does only the compressor run on my ClimateMaster Heat Pump?
    • J
      james81Sep 12, 2025
      If only the compressor runs on your ClimateMaster Heat Pump, check the G wiring at the heat pump. Jumper G and R for fan operation. Check the fan motor relay by jumpering G and R for fan operation and check for Line voltage across BR contacts. Check the fan power enable relay operation (if present). Check for line voltage at the motor and inspect the capacitor. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode. Set for cooling demand and check 24VAC on RV coil and at CXM/DXM2 board for the reversing valve. Check for ‘O’ RV setup not ‘B’ for thermostat setup. Check O wiring at heat pump and jumper O and R for RV coil ‘click’.

Summary

Model Nomenclature - General Overview

General Information

Safety Precautions

Details DANGER, WARNING, CAUTION, and NOTICE statements for safe operation.

Inspection, Storage, and Unit Protection

Covers equipment inspection upon receipt, storage guidelines, and job site protection.

Installation Procedures

Pre-Installation Steps

Outlines essential steps to prepare units before installation begins.

Horizontal Installation Guidelines

Covers unit location, mounting, pitch, and conversion for horizontal units.

Vertical Installation Guidelines

Covers unit location, mounting, sound attenuation, and condensate for vertical units.

Piping Installation Requirements

Provides guidelines for proper supply, return, and loop piping installation, including material warnings.

System Application Types

Water-Loop Heat Pump Applications

Discusses considerations for commercial systems connected to a common piping loop.

Ground-Loop and Ground-Water Applications

Details pre-installation, piping, antifreeze, water quality, and control valve requirements.

Dimensional Data and Service Access

Horizontal Unit Dimensions

Provides cabinet, water connection, and discharge/return dimensions for horizontal units.

Vertical Unit Dimensions

Provides cabinet, water connection, and electrical knockout dimensions for vertical units.

WSE Unit Dimensions

Details dimensional data for TCH/TCV units with Waterside Economizer options.

Service Access Guidelines

Illustrates and details service access points for horizontal and vertical units.

Electrical and Control System Information

Electrical Data Tables

Presents electrical data for standard, high static, ECM, and constant volume units.

Line Voltage and Low Voltage Wiring

Covers line voltage, low voltage wiring, power connections, and thermostat wiring.

Control System Operation (CXM;DXM2)

Details CXM and DXM2 control features, DIP settings, fault codes, and start-up procedures.

Blower Performance Data

TC Series Blower Performance Tables

Provides detailed blower performance data (CFM, Power) for various TC models across static pressures.

Unit Maintenance and Troubleshooting

Preventive Maintenance Procedures

Covers maintenance for water coils, condensate drains, motors, and refrigerant systems.

Troubleshooting Guides

Provides fault-cause-solution tables for functional and performance issues.

Unit Start-Up Procedures

Step-by-step start-up procedures and a log sheet for recording operational data.

Warranty Information

U.S. & Canada and International Warranty

Outlines limited express warranty terms, limitations, and remedies for all regions.

ClimateMaster Tranquility TCH 048 Specifications

General IconGeneral
BrandClimateMaster
ModelTranquility TCH 048
CategoryHeat Pump
LanguageEnglish