EasyManua.ls Logo

ClimateMaster Tranquility TCH 009 - User Manual

ClimateMaster Tranquility TCH 009
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Tranquility
®
16
COMPACT (TC) Series
MODELS TCH/V 006 - 60
60 HZ - HFC-410A
INSTALLATION, OPERATION
& MAINTENANCE
97B0075N07
Revised: July 7, 2020
Table of Contents
Model Nomenclature – General Overview 3
General Information 4
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
TC - Horizontal – Dimensional Data 20
TCH with WSE – Dimensional Data 22
TC - Horizontal Service Access 24
TC - Vertical Upow – Dimensional Data 25
TCV with WSE – Dimensional Data 27
TC - Vertical Service Access 29
Electrical Data – Standard Unit 30
Electrical Data – High Static Blower 31
Electrical Data – Constant Torque ECM 32
Electrical Data – Constant Volume ECM 33
Electrical – Line Voltage 34
Eletctical – Power & Low Voltage Wiring 35
Electrical – Low Voltage Wiring 36
Electrical – Thermostat Wiring 37
Blower Performance Data – TC006 38
Blower Performance Data – TC009 39
Blower Performance Data – TC012 40
Blower Performance Data – TC015 41
Blower Performance Data – TC018 42
Blower Performance Data – TC024 43
Blower Performance Data – TC030 44
Blower Performance Data – TC036 45
Blower Performance Data – TC041 46
Blower Performance Data – TC042 47
Blower Performance Data – TC048 48
Blower Performance Data – TC060 49
Constant Volume ECM Control 50
Wiring Diagram Matrix 52
DIP Setting Table 53
CXM Controls 54
DXM2 Controls 55
Safety Features – CXM and DXM2 Controls 60
Unit Starting and Operating Conditions 62
Piping System Cleaning and Flushing 63
TC with Waterside Economizer Option 64

Table of Contents

Questions and Answers

  • J
    John SotoAug 18, 2025
    How to troubleshoot main power problems in my ClimateMaster Heat Pump?
    • S
      Scott CarterAug 18, 2025
      If the green status LED is off on your ClimateMaster Heat Pump, start by checking the line voltage circuit breaker and disconnect. Also, check for line voltage between L1 and L2 on the contactor. Further, verify that there is 24VAC between R and C on CXM/DXM2. Finally, examine the primary and secondary voltage on the transformer.
  • M
    Monica GatesAug 23, 2025
    What causes LP/LOC Fault Code 3 (Low Pressure / Loss of Charge) in a ClimateMaster Tranquility TCH 009?
    • A
      Amanda SantiagoAug 23, 2025
      If your ClimateMaster Heat Pump shows a Low Pressure/Loss of Charge fault (Code 3), it might be due to insufficient charge. Check for refrigerant leaks. Also, check the charge and start-up water flow.
  • C
    cchambersAug 25, 2025
    Why does my ClimateMaster Tranquility TCH 009 show LT1 Fault Code 4 (Water coil low temperature limit)?
    • K
      Katherine ChavezAug 26, 2025
      If your ClimateMaster Heat Pump displays a Water coil low temperature limit fault (LT1 Fault Code 4), it could be due to several reasons. Start by checking the pump operation or water valve operation/setting if there is reduced or no water flow in heating. Clean or replace the plugged strainer or filter. Ensure the water flow is adjusted to the proper rate. Check the antifreeze density with a hydrometer to ensure an adequate level. If using antifreeze, clip the JW3 jumper for antifreeze (10°F [-12°C]) use. Ensure the water temperature is within design parameters. Finally, check the thermistor's temperature and impedance correlation per the chart; replace if it's bad.
  • C
    Claudia HerreraAug 27, 2025
    What does LT2 Fault Code 5 (Air coil low temperature limit) mean on my ClimateMaster Heat Pump?
    • S
      swoodwardAug 27, 2025
      If your ClimateMaster Heat Pump is showing an Air coil low temperature limit fault (LT2 Fault Code 5), it could be due to several reasons. First, check for a dirty air filter and clean or replace it if there is reduced or no air flow in cooling. Check the fan motor operation and airflow restrictions. Check the static pressure against the blower table if the external static is too high. Ensure the entering air temperature is within design parameters. If the temperature limit setting is improper (30°F vs 10°F [-1°C vs -12°C]), normal airside applications will require 30°F [-1°C] only. Finally, check the thermistor's temperature and impedance correlation per the chart if it's bad.
  • P
    Patrick BlanchardAug 29, 2025
    How do I fix Condensate Fault Code 6 on my ClimateMaster Tranquility TCH 009?
    • B
      Bobby BellAug 29, 2025
      If your ClimateMaster Heat Pump displays Condensate Fault Code 6, it could be caused by a blocked drain. Check for blockage and clean the drain. Inspect the trap dimensions and ensure its location is ahead of the vent. Check for proper piping slope away from the unit to ensure good drainage. Ensure the unit slopes toward the outlet. Check the vent location for poor venting. Check for moisture shorting to the air coil if there's moisture on the sensor. Replace the air filter if it is plugged. Find and eliminate any restrictions to return airflow, and consider increasing the return duct and/or grille size.
  • T
    tgallagherSep 1, 2025
    What does Over/Under Voltage Code 7 mean for my ClimateMaster Tranquility TCH 009?
    • S
      Sandra MillerSep 1, 2025
      If your ClimateMaster Heat Pump is showing Over/Under Voltage Code 7 (Auto resetting), it may be due to under voltage. Check the power supply and 24VAC voltage before and during operation. Also, check the power supply wire size. Check compressor starting and consider if a hard start kit is needed. Verify the 24VAC and unit transformer tap for correct power supply voltage. If it is due to over voltage, check the power supply voltage and 24VAC before and during operation. Also, check the 24VAC and unit transformer tap for correct power supply voltage.
  • R
    Ryan WhitneySep 3, 2025
    What does Unit Performance Sentinel Code 8 mean on my ClimateMaster Tranquility TCH 009 Heat Pump?
    • R
      ruizjuanSep 3, 2025
      If your ClimateMaster Heat Pump displays Unit Performance Sentinel Code 8, it could be due to the following reasons. In heating mode, if LT2 is greater than 125°F [52°C], check for poor airflow or an overcharged unit. In cooling mode, if LT1 is greater than 125°F [52°C] or LT2 is less than 40ºF [4ºC], check for poor water flow or airflow.
  • G
    Gabriel WilsonSep 6, 2025
    Why is my ClimateMaster Tranquility TCH 009 short cycling?
    • A
      Amy HernandezSep 6, 2025
      If your ClimateMaster Heat Pump is short cycling, it could be due to a dirty air filter; check and clean the air filter. The unit might be in 'test mode'; reset power or wait 20 minutes for auto exit. The unit may be oversized for the space; check the sizing for the actual load of the space. Check the compressor overload and replace if necessary.
  • A
    Amy HarveySep 8, 2025
    What causes only the fan to run on my ClimateMaster Tranquility TCH 009?
    • C
      Cheryl PeckSep 8, 2025
      If only the fan is running on your ClimateMaster Heat Pump, ensure the thermostat is set for heating or cooling operation. Check for lockout codes and reset power if necessary. Inspect the compressor overload and replace if needed. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode.
  • P
    pwhiteSep 10, 2025
    Why does only the compressor run on my ClimateMaster Tranquility TCH 009?
    • A
      Angela ColemanSep 12, 2025
      If only the compressor runs on your ClimateMaster Heat Pump, check the G wiring at the heat pump. Jumper G and R for fan operation. Check the fan motor relay by jumpering G and R for fan operation and check for Line voltage across BR contacts. Check the fan power enable relay operation (if present). Check for line voltage at the motor and inspect the capacitor. Check the thermostat wiring at the heat pump; jumper Y and R for compressor operation in test mode. Set for cooling demand and check 24VAC on RV coil and at CXM/DXM2 board for the reversing valve. Check for ‘O’ RV setup not ‘B’ for thermostat setup. Check O wiring at heat pump and jumper O and R for RV coil ‘click’.

Summary

Model Nomenclature - General Overview

General Information

Safety Warnings and Cautions

Provides critical safety information, including DANGER, WARNING, and CAUTION notices for safe operation.

Horizontal Installation

Horizontal Unit Location

Guidelines for selecting suitable indoor locations for horizontal unit installation, ensuring service access.

Mounting Horizontal Units

Instructions on how to properly mount horizontal units using factory-provided hanger brackets.

Vertical Installation

Electrical Data - Standard Unit

Electrical Wiring

ECM Blower Control

Constant Volume ECM Control

Explains the operation and control of the Constant Volume ECM blower motor via the DXM2 control board.

Control System Configuration

DIP Setting Table

Provides tables for configuring unit operation via DIP switch settings for various control and economizer options.

CXM Controls

Information on CXM control features, test modes, and field configuration options for unit operation.

DXM2 Controls

Details DXM2 control features, test modes, DIP switches, and jumpers for system configuration.

Safety Features

Safety Features - CXM and DXM2 Controls

Details safety features like anti-short cycle, low pressure, temperature limits, and lockout conditions for component protection.

Unit Starting and Operating Conditions

Unit Start-up Procedure

Step-by-step instructions for performing unit start-up and initial checks, including temperature and pressure measurements.

Troubleshooting

Functional Troubleshooting

Lists common faults and their possible causes and solutions for heating and cooling operational issues.

Performance Troubleshooting

Addresses issues like insufficient capacity, high head pressure, and low suction pressure for optimal performance.

ClimateMaster Tranquility TCH 009 Specifications

General IconGeneral
EER12.5
SEER16.0
HSPF9.0
Phase1
RefrigerantR-410A

Related product manuals