PRIME
DETERGENT
CONCENTRATION
PRIME
SANITIZER
CONCENTRATION
PRIME
RINSE
CONCENTRATION
FLUSH
OFF
ON
11-2017
GW-100 Carousel
Glasswasher
Quick Setup
Instructions
1
STEP
Connect the drain hose to the FLOOR DRAIN. If
floor drain is not available connect to the wall. Floor
drain must have a (1 inch) air gap between the drain
hose and the floor drain.
Adjust heater thermostat to 140F.
Connect water lines (hot 140F/160F) and (cold
75F) to water solenoid valves.
Flip power "on-off/flush" switch to "ON" position.
Wash tank will automatically fill.
Connect L1 and L2 leads to the power block and
ground wire to ground lug.
4
STEP
PRIME
RINSE
CONCENTRATION
FLUSH
OFF
ON
Level dishmachine by adjusting leveling legs.
Dishmachine must be level front and back to
ensure proper performance.
GROUND
L2
(N)
L1
HOT WATER
INLET
2
COLD WATER
INLET
2
2
STEP
5
STEP
6
STEP
140
3
STEP
FLOOR
DRAIN
1"AIR GAP
WALL
DRAIN
WARNING: Electrical and plumbing
connections need to be made by a
licensed service person and comply
with all Federal, State and Local
Health, Electrical, Plumbing and
Safety codes.
HEATER THERMOSTAT
POWER BLOCK
1
POWER SWITCH
5
6
THERMOMETER
DRAIN CONNECTION
3
LEVELING LEGS
4
6
PN: 1013039