08-2021
3
STEP
4
STEP
1
STEP
H-1X
Quick Setup
Instructions
WARNING: Electrical and
plumbing connections need
to be made by a qualified
service person who will
comply with all available
Federal, State and Local
Health, Electrical, Plumbing
and Safety codes.
LINE 1
LINE 2
208/230V
GROUND
2
STEP
FLOOR DRAIN
1"AIR GAP
WALL DRAIN
ELECTRICAL CONNECTIONS
LOCATED INSIDE FRONT
PANEL
Level dishmachine by adjusting leveling legs.
Dishmachine must be level front to back and
side to side ensure proper performance.
Connect lines 1 and 2 to electrical block located
inside front panel.
Connect dishmachine to hot water source, minimum
temperature 120F, better results at 140F.
LEVELING
LEGS
3
1/2" WATER
INLET
4
3/4" DRAIN
OUTLET
2
1
Connect the drain hose to wall or floor drain. The
floor drain must have a 1 inch air gap between
drain hose and floor drain.
PN: 00000.00
THE DRAIN HOSE IS LOOPED
AND CLAMPED AND MUST
NOT BE CHANGED. ALTERING
THE DRAIN HOSE ROUTING
MAY RESULT IN THE MACHINE’S
INABILITY TO DRAIN OR MAY
CAUSE THE MACHINE TO
SIPHON THE WATER OUT OF
THE MACHINE.
! VERY IMPORTANT !
The dishwasher will not drain
correctly if it is connected to a
disposer.
H-1X

Other manuals for CMA Dishmachines H-1X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CMA Dishmachines H-1X and is the answer not in the manual?

CMA Dishmachines H-1X Specifications

General IconGeneral
ModelH-1X
PowerElectric
Voltage208-240V
Weight250 lbs
Wash Temperature150°F
Rinse Temperature180°F
Power Requirements208-240V, 60Hz, 1 phase