15
ENGLISH
Troubleshooting guide
Thedehumidifier
will not switch on.
• Make sure that themains lead is properly plugged in and that there
is power in thewall socket.
• Thewater reservoir is full or incorrectly fitted.
• Theset humidity level has been reached.
Thehumidity is
not reducing.
• Thedehumidifier has not been used long enough.
• Make sure that nothing is preventing theair in theroom where
thedehumidifier is used from circulating properly.
• Thehumidity level is not set low enough.
• Make sure that no outdoor air can enter theroom in which
thedehumidifier is being used.
• Theambient temperature is below 15 ºC.
• Is there aheat source in theroom which is raising thehumidity?
Unusual noises
emitted during use.
• Make sure that theair filter is clean.
• Thedehumidifier is tilted or standing on anuneven surface.
Error and protection
codes (shown on
thedehumidifier’s
display)
• AS: Defective humidity sensor. Turn off theair conditioner, pull out
theplug and plug it in again. If this does not solve theproblem,
contact aqualified service centre.
• ES: Defective temperature sensor. Turn off theair conditioner,
pull out theplug and plug it in again. If this does not solve
theproblem, contact aqualified service centre.
• P1: Automatic defrosting in progress. Let thedehumidifier be switched
on until P1 no longer appears on thedisplay.
• P2: Thewater reservoir is full or incorrectly fitted. Empty of refit it.
• E3: Other defects. Turn off theair conditioner, pull out theplug
and plug it in again. If this does not solve theproblem, contact
aqualified service centre.
Responsible disposal
This symbol indicates that this product should not be disposed of with general
household waste. This applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards caused by incorrect waste
disposal, theproduct must be handed in for recycling so that thematerial can
be disposed of in aresponsible manner. When recycling your product, take it to
your local collection facility or contact theplace of purchase. They will ensure that
theproduct is disposed of in anenvironmentally sound manner.
Specifications
Power supply 220–240 V, 50 Hz
Power 415 W
Dehumidification capacity Up to 20 l/day
Reservoir capacity 3 l
Operating temperature 5– 35 ºC
Coolant R290
Size 51×35×21 cm
Weight 13 kg